Installation
72
The nozzles not provided are available at Authorised Service Centres.
8 LPG G30/31 AUX SR R UR2 Oven
Rated heating capacity (kW)
1.01.752.9 4.2 4.2
Nozzle diameter (1/100 mm)
50 65 85 91+46 98
Pre-chamber (printed on nozzle)
----(H1)
Reduced flow rate (W)
400 500 800 1900 900
Rated flow rate G30 (g/h)
73 127 211 305 305
Rated flow rate G31 (g/h)
71 125 207 300 300
9 LPG G30/G31 – 37 mbar AUX SR R UR2 Oven
Rated heating capacity (kW)
1.0 1.8 2.9 4.2 4.2
Nozzle diameter (1/100 mm)
50 65 81 85+46 95
Pre-chamber (printed on nozzle)
----(H1)
Reduced flow rate (W)
450 550 800 1900 1100
Rated flow rate G30 (g/h)
73 131 211 305 305
Rated flow rate G31 (g/h)
71 129 207 300 300
10 LPG G30/G31 – 50 mbar AUX SR R UR2 Oven
Rated heating capacity (kW)
1.0 1.8 2.9 4.2 4.2
Nozzle diameter (1/100 mm)
43 58 74 70+43 85
Pre-chamber (printed on nozzle)
(H2) (M) (Z) (S1H2) (Z)
Reduced flow rate (W)
400 500 800 1900 1000
Rated flow rate G30 (g/h)
73 131 211 305 305
Rated flow rate G31 (g/h)
71 129 207 300 300