Scope of Delivery
After unpacking all parts, check for any damage
in transit.
If you have any complaints, please contact the dealer
from whom you purchased the appliance or our
Customer Service department.
The following parts are included:
Built-in appliance
Interior fittings (depending on model)
Bag containing installation materials
Operating Instructions
Installation Instructions
Customer Service Booklet
Warranty enclosure
Information on the energy consumption and noises
Connecting the Appliance
Have a technician install and connect the appliance
according to the enclosed Installation Instructions.
Do not remove the transportation protection devices
from the shelves and storage compartments until
the appliance has been installed.
Always connect the water before the power.
Apart from statutory national regulations, you should
comply with all applicable local electricity and water
companies codes and requirements.
After installing the appliance, wait at least 1 hour before
switching the appliance On. During transportation
the oil in the compressor may have flowed into
the refrigeration system.
Before switching the appliance On for the first time,
clean the interior of the appliance (see chapter
“Cleaning the Appliance”).
Water Connection
, CAUTION:
Connect the appliance to a drinking water line
only:
Minimum pressure: 0.2 Mpa (2 bar)
Maximum pressure: 0.8 Mpa (8 bar)
Pressure over 0.8 MPa (8 bar): install
a pressure limiter between drinking water
connection and hose set:
The water may be connected only by a competent fitter
according to the local regulations of the appropriate
Water Supply company.
A cold water connection is necessary for operating
the automatic Ice Maker. The water pressure must be
between 29 and 116 p.s.i. (2.0 and 8.0 bar). The
installation must correspond to the local plumbing
regulations.
A separate Shut-Off-Valve should be installed in
the cold-water inflow.
The Shut-Off-Valve should not be located behind
the appliance. It is recommended that you mount
the Shut-Off-Valve directly next to the appliance or at
another place that is easily accessible.
When installing the water connection, pay attention to
the permissible installation area for the water line.
For connection to the drinking water line use only water
pipes that are suitable for drinking water. Observe
national regulations and the connection conditions of
the local Water Supply companies.
Electrical Connection
, WARNING:
Risk of electric shock:: Connect the appliance to
a grounded, 3-phase outlet only. Never remove
the ground phase. Do not use any adapters. Do
not use any extension leads.
, WARNING:
Risk of electric shock:: Incorrect connection of
the appliance may result in death, fire or electric
shock.
Improper connection of the protective conductor
may result in electric shock. If you are in doubt
as to whether the appliance has been properly
grounded, have it tested by a qualified electrician
or Customer Service technician.
, WARNING:
Risk of electric shock:: If the length of the power
cord is inadequate, never use multiple outlets or
extension leads. Instead, please contact
Customer Service for alternatives.
This appliance must be connected to a permanently
installed outlet.
The outlet must be near the appliance and also freely
accessible following installation of the appliance.
The appliance complies with protection class I. Connect
it to a correctly installed outlet. Correct means: with a
protective conductor, 110 V 120 V/ 60 Hz alternating
current. The outlet must be protected by a 10 A 16 A
fuse.
The appliance comes with a UL registered 3-wire power
cord. The appliance requires a 3-pole outlet.
Please observe the following table with regard to this:
Check on the rating plate whether the indicated voltage
and current type match the values of your power
supply. The position of the rating plate can be found in
the chapter entitled “Customer Service”.
, WARNING:
Never connect the appliance to electronic
energy saving devices.
Our appliances can be used with mains and
sinecontrolled inverters. Mains-controlled
inverters are used for photovoltaic systems
which are connected directly to the national grid.
Sine-controlled inverters must be used for
isolated applications (e.g. on ships or in
mountain lodges) which are not connected
directly to the national grid.
Appliance Maximum Simultaneous Load
Fridge-
freezer
6.0 amps