Electrolux RH30WC55GS 30'' Chimney Wall-Mount Hood

User Manual - Page 16

For RH30WC55GS. Also, The document are for others Electrolux models: RH30WC55GSB, RH36WC55GSB

PDF File Manual, 21 pages, Read Online | Download pdf file

RH30WC55GS photo
Loading ...
Loading ...
Loading ...
1616
1616
16
Special functions
Clock prClock pr
Clock prClock pr
Clock pr
ogrammingogramming
ogrammingogramming
ogramming
tThe clock can be reprogrammed at any time except during an active timed function.
tThe clock can be displayed in a twelve hour format and valid clock times are from 1:00 to 12:59.
tThe clock can be reprogrammed pressing the
TT
TT
T
imerimer
imerimer
imer” button for 5 seconds, and after, the clock can be
adjusted with the “ ” and “ ” buttons. Colon “:” will ash indicating clock programming mode.
tThe user can have minute increments / decrements of 1 minute, but if the user keep pressing the ”/
buttons for more than 1 second, the increments / decrements will be of 5 minutes.
During this option the control will round to the nearest 5 minutes.
tThe user can nish on reprogramming the clock pressing the “
TT
TT
T
imerimer
imerimer
imer” button.
tAfter 1 minute of no button pressed the control will accept the programmed clock time and will add one
minute to the set clock.
GrGr
GrGr
Gr
ease lter saturation alarmease lter saturation alarm
ease lter saturation alarmease lter saturation alarm
ease lter saturation alarm
tAfter thirty fan functional hours, the display will show
GrGr
GrGr
Gr
ease Filterease Filter
ease Filterease Filter
ease Filter” if the fan is active.
When this icon is shown in the display, the grease lters installed are required to be washed.
tTo reset the grease lter saturation alarm the user must press the “ button for 5 seconds, after this
action the icon “
GrGr
GrGr
Gr
ease lterease lter
ease lterease lter
ease lter” is not displayed, and the hood has the normal display operation.
CharChar
CharChar
Char
coal lter saturation alarm (Recircoal lter saturation alarm (Recir
coal lter saturation alarm (Recircoal lter saturation alarm (Recir
coal lter saturation alarm (Recir
culating accessories)culating accessories)
culating accessories)culating accessories)
culating accessories)
tAfter one hundred and twenty functional hours of the fan, the display will show
CharChar
CharChar
Char
coal Filtercoal Filter
coal Filtercoal Filter
coal Filter” if the fan
is active. When this icon ashes on display, the charcoal lters installed are required to be replaced or
reactivated.
tTo reset the charcoal lter saturation indication the user must press the “ ” button for 5 seconds, after
this time the icon “
CharChar
CharChar
Char
coal ltercoal lter
coal ltercoal lter
coal lter” is not displayed and the hood has the normal display operation.
Audible signal activation and deactivationAudible signal activation and deactivation
Audible signal activation and deactivationAudible signal activation and deactivation
Audible signal activation and deactivation
tThe audible signals can be activated or deactivated pressing the “
LightLight
LightLight
Light” button for 5 seconds.
tIf the audible signal is activated, a tone must sound and the “
SndSnd
SndSnd
Snd” symbol must appear on the display for
2 seconds.
tIf the audible signal is deactivated, the “
SndSnd
SndSnd
Snd” symbol must appear on the display for 2 seconds and no
tone must sound.
CharChar
CharChar
Char
coal lter inclusion and exclusion (Recircoal lter inclusion and exclusion (Recir
coal lter inclusion and exclusion (Recircoal lter inclusion and exclusion (Recir
coal lter inclusion and exclusion (Recir
culating accessories)culating accessories)
culating accessories)culating accessories)
culating accessories)
tThe charcoal lter inclusion or exclusion can be set by pressing the “ ” and “ buttons at the same
time for 5 seconds.
tThe Inclusion or exclusion of charcoal lter must be selected while the lamps and the motor are OFF.
tWhen the charcoal lter has been excluded, the charcoal lter alarm is disabled.
Heat sensorHeat sensor
Heat sensorHeat sensor
Heat sensor
tThe control is equipped with a heat sensor that will turn on the blower at second speed if excessive heat
occurs (over
158° F158° F
158° F158° F
158° F or
70°C70°C
70°C70°C
70°C) surrounding the control area.
tIf the blower is OFF or if it is operating at rst speed, the blower will be set automatically to second speed,
the display shows the word "
CArECArE
CArECArE
CArE" to indicate that heat sensor has detected an excessive heat.
tDuring this state, the user may raise the blower speed to third speed but can not decrease the speed.
tWhen the temperature level on the hood drops to normal, the blower will operate in the setting dened by
the user before the alarm occured.
Control buttons - Special functions
Loading ...
Loading ...
Loading ...