44 Part Number: 000015430 Rev 02 5/20
Step 6 Mix a solution of cleaner/descaler and
lukewarm water. Depending upon the amount of mineral
buildup, a larger quantity of solution may be required.
Use the ratio in the table below to mix enough solution to
thoroughly clean all parts.
Solution Type Water Mixed With
Cleaner 1 gal. (4 L) 16 oz (475 ml) cleaner
Step 7 Use 1/2 of the descaler/water mixture to
descale all components. The solution will foam when it
contacts lime scale and mineral deposits; once the foaming
stops use a soft-bristle nylon brush, sponge or cloth (NOT
a wire brush) to carefully clean the parts. Soak parts for 5
minutes (15 - 20 minutes for heavily scaled parts). Rinse all
components with clean water.
Notice
Do not clean the ice thickness probe in a dishwasher.
Permanent damage to the ice thickness probe will occur.
Ice Thickness Probe & Water Level Probe
Clean the probes using the following procedure.
NOTE: Do not soak electrical connectors in cleaner or
sanitizer solution.
1. Mix a solution of Manitowoc ice machine cleaner/
descaler and water (2 ounces of cleaner/descaler to
16 ounces of water) in a container.
2. Clean all probe surfaces including all plastic parts
(do not use abrasives). Verify all surfaces are clean.
Thoroughly rinse probes with clean water.
3. Reinstall probe, then sanitize the ice machine and bin/
dispenser interior surfaces.