192 Part Number: 000015430 Rev 02 5/20
CLEANUP PROCEDURE
Mild System Contamination
1. Replace any failed components.
2. If the compressor is good, change the oil.
Pour the oil from the compressor into a graduated
vessel and replace with the same amount removed.
3. Replace the liquid line drier.
NOTE: If the contamination is from moisture, use heat
lamps during evacuation. Position them at the compressor,
condenser and evaporator prior to evacuation. Do not
position heat lamps too close to plastic components, or
they may melt or warp.
Important
Dry nitrogen is required for this procedure to prevent
refrigerant release.