Product Description
The DP01A on Amana
®
Brand AX is a compact embedded
processor platform with flash memory for backup. It provides
integrated control, supervision, as well as direct, on-board I/
O for monitoring and control of Amana
®
Brand PTAC’s with
wireless DT01A Antennae.
Installing The Amana
®
Brand AX
Now that you have installed the DigiSmart devices on all of
your Guestroom PTAC units, you are ready to install the
Amana
®
Brand AX Platform.
Let’s review a short checklist.
1. Room Numbers have all been configured in each PTAC/
PTHP unit equipped with DigiSmart devices. This is ex-
tremely important since the Amana
®
Brand AX will con-
figure the screen graphics based upon those room
numbers. If you have not configured the room numbers,
the Amana
®
Brand AX cannot distinguish one room from
another.
2. You have selected a location for the Amana
®
Brand AX
that is within 75 feet of at least 1 of the rooms with
DigiSmart devices. Your wireless HotelLink Network will
work most efficiently if the Amana
®
Brand AX is close to
several units, but it is essential that it be within 75 feet
of at least 1 unit.
HIGH VOLTAGE!
Failure to do so may cause property
damage, personal injury or death.
Disconnect ALL power before servicing or
installing this unit. Multiple power sources
may be present.
Safety Precautions
1. Make sure all connections are in accordance with na-
tional and local electrical codes. Use copper conduc-
tors only.
2. To reduce the risk of fire or electrical shock, install in a
controlled environment, relatively free of contaminants.
Special Notes - Picking a Location
The Amana
®
Brand AX should be mounted to a wall surface
no more than 6 ft. high at the top of the enclosure.
This product is intended for indoor use only. The unit should
not be exposed to ambient conditions outside of the range of
0°C (32° F) to 50°C (122° F) and relative humidity outside the
range 5% to 95% non-condensing (pollution degree 1).
The unit is designed to be wall mounted with the battery
situated towards the bottom of the unit. For proper airflow at
temperature extremes, do not mount the unit oriented in any
other way.
© 2006 Goodman Company, L.P.
®
is a trademark of Maytag Corporation and is used under
license to Goodman Company, L.P. All rights reserved.
The following installation instructions are for a typical installation.
Please contact your PTAC salesperson for additional assistance and explanation
prior to ordering materials or cutting openings.
ATTENTION INSTALLING PERSONNEL
As a professional installer, you have an obligation to know the product better than the customer.
This includes all safety precautions and related items.
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warnings.
Remember, it is your responsibility to install the product safely and to know it well enough
to be able to instruct a customer in its safe use.
Safety is a matter of common sense...a matter of thinking before acting.
Most dealers have a list of specific, good safety practices...follow them.
The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there is a direct conflict
between existing practices and the content of this manual, the precautions listed here take precedence.
Loading ...
Loading ...
Loading ...