Smeg Gas Cooker TR4110RO Victoria Aesthetic

User Manual - Page 32

For TR4110RO.

PDF File Manual, 40 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Installation
74
When the job is complete, the installer must
issue a certificate of conformity.
1 Extraction using a hood.
2 Extraction without a hood.
A Single natural draught chimney.
B Single chimney with extractor fan.
C Directly outdoors with wall- or window-
mounted extractor fan.
C Directly outdoors through wall.
Air
Combustion products
Extractor fan
5.2 Adaptation to different types of
gas
In case of operation with other types of gas,
the burner nozzles must be changed and
the minimum flame adjusted on the gas
taps.
Replacing nozzles
1. Remove the pan stands, burner caps and
flame-spreader crowns to access the
burner casings.
2. Replace the nozzles using a 7 mm socket
wrench according to the gas to use (see
Burner and nozzle characteristics tables).
3. Replace the burners in the correct
position.
Loading ...
Loading ...
Loading ...