Remote Condenser Models - User Manual
May 2017
Page 11
Plumbing Requirements
All models require connection to cold, potable water.
A hand actuated valve within site of the machine
is required. There is a single 3/8” FPT inlet water
connection on the back of the cabinet.
Water Filters
Install a new cartridge if the lters were used with a
prior machine.
Drains
All models require drain tubing to be attached to them.
There is a single ¾” FPT drain tting in the back of the
cabinet.
Install new tubing when replacing a prior ice machine,
as the tubing will have been sized for the old model
and might not be correct for this one.
1. Connect water supply to water inlet ttings.
2. Connect drain tubing to drain tting.
3. Route the drain tubing to building drain. Follow
local codes for air gap.
4. Use rigid drain tubes and route them separately –
do not Tee into the bin’s drain.
Vent the reservoir drain. A vertical vent at the back of
the drain, extended about 8 – 10” will allow the gravity
drain to empty and also keep any surges during
draining from discharging water.
Horizontal runs of drain tubing need a ¼” per fall per
foot of run for proper draining.
Follow all applicable codes.
Reservoir Drain
Water Supply
Connection
Potable
Water
Supply
Bin Drain
Vent for
Reservoir
Drain