Installation Manual 15
ENGLISH
Installation
Connecting the piping to the indoor unit
and drain hose to drain pipe.
1. Align the center of the pipes and
sufficiently tighten the flare nut by hand.
2. Tighten the flare nut with a wrench.
3. Next, extend the indoor unit's drain hose.
Then attach the drain pipe.
Indoor unit tubing Flare nut Pipes
Wrench
Indoor unit tubing
Open-end wrench (fixed)
Connection pipe
Flare nut
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
mm inch kgf.m (lbf·ft)
Ø6.35 1/4 1.8~2.5 (13~18)
Ø9.52 3/8 3.4~4.2 (24~30)
Ø12.7 1/2 5.5~6.6 (40~48)
Outside diameter Torque
Installation Information. For left piping. Follow the instruction below.