Loading ...
Loading ...
Loading ...
wolfappliance.com
|
5
SPECIFICATIONS
Gas Supply
Installation must comply with local codes or, in the absence
of local codes, with the National Fuel Gas Code.
Locate the gas supply as shown in the illustrations on the
following pages.
The cooktop is equipped for use with natural or liquid
propane (LP) gas. It is design certied by the Canadian
Standards Association (CSA) for natural or LP gases. The
product rating plate has information on the type of gas that
should be used. For rating plate location, refer to the illustra-
tion below. If this information does not agree with the type
of gas available, check with the local gas supplier. The gas
pressure regulator is built into the unit.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
The cooktop must be connected to a regulated gas supply.
The supply line must be equipped with an approved external
gas shut-off valve located near the cooktop in an accessible
location. Do not block access to the shut-off valve. Refer to
the illustration below.
A gas supply of
3
/4" (19) ID line must be provided to the
cooktop. If local codes permit, a certied, 3'
(.9 m) long,
1
/2" (13) or
3
/4" (19) ID exible metal appliance connector is
recommended to connect the units
1
/2" NPT male inlet to
the gas supply line. Pipe joint compounds, suitable for use
with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected
from the gas supply piping system during any pressure
testing of the system at test pressures in excess of .5 psi
(3.5 kPa)
. The appliance must be isolated from the gas
supply piping system by closing its individual manual shut-
off valve during any pressure testing of the system at test
pressures equal to or less than .5 psi
(3.5 kPa).
Wolf natural gas cooktops will function up to 10,250'
(3124 m)
in altitude without adjustment and LP gas cooktops
will function up to 8,600'
(2621 m). If the installation exceeds
these elevations, contact your authorized Wolf dealer for a
high altitude conversion kit.
SHUT-OFF VALVE
OPEN POSITION
GAS SUPPLYTO APPLIANCE
Gas shut-off valve
Rating plate location
RATING PLATE
Loading ...
Loading ...
Loading ...