Loading ...
Loading ...
3
Specifications
Model GXSH40V GXSH45V
Rated Capacity* (Grains@ Salt Dose) 11,700 @ 2.3 lbs
31,500 @ 8.7 lbs.
40,000 @ 15.1 lbs.
13,200 @ 2.6 lbs
35,500 @ 9.9 lbs.
45,100 @ 17.0 lbs.
Rated Efficiency** (Grains/Pound of Salt @ Minimum Salt Dose) 5,090 @ 2.3 lbs. 5,050 @ 2.6 lbs.
Water used during Regeneration (gallons/grains) 2.7 /1000 2.8 /1000
Total Water Used per Regeneration @ Maximum Salt Dose 37.0 gallons 43.0 gallons
Amount of High Capacity Ion Exchange Resin (lb/cu.ft.) 57.56/1.11 65.0/1.25
Resin Tank Nominal Size (in., dia. x height) 9 x 40 10 x 40
Service Flow Rate (gpm) 9.5 9.5
Pressure Drop at Rated Service Flow (psig) 12.7 10.3
Water Supply Maximum Hardness (gpg) 110 160
Water Supply Maximum Clear Water Iron (ppm)*** 8 10
Water Pressure Limits (minimum-maximum psi)**** 20-125 20-125
Water Temperature Limits (minimum-max. °F) 40-120 40-120
Maximum Flow Rate to Drain (gpm) 2.3 2.3
Specifications and Performance Claims
These systems conform to NSF/ANSI 44 for
the specific capacity claims as verified and
substantiated by test data.
* Testing was performed using pellet grade
sodium chloride as
the regenerant salt.
** Efficiency rating is valid only at the lowest
stated salt dosage. These softeners were
efficiency rated according to NSF/ANSI 44.
*** Extent of iron removal may vary with
conditions. The capacity to reduce clear
water iron is substantiated by WQA test data.
State of Wisconsin requires additional treatment if water supply contains greater than 5 ppm clear water iron.
Refer to Cleaning Iron Out of the Water Softening System section.
**** Canada working pressure limits: 1.4–7.0 kg/cm
2
.
This model is efficiency rated. The efficiency rating is valid only at the minimum stated salt dose. The softener has
a demand initiated regeneration (D.I.R) feature that complies with specific performance specifications intended to
minimize the amount of regenerant brine and water used in its operation.
The softener has a rated salt efficiency of not less than 4,000 grains of total hardness exchange per pound of
salt (based on sodium chloride), and shall not deliver more salt than its listed rating or be operated at a sustained
maximum service flow rate greater than its listed rating. This softener has been proven to deliver soft water for at
least ten continuous minutes at the rated service flow rate. The rated salt efficiency is measured by laboratory test
described in NSF/ANSI Standard 44. These tests represent the maximum possible efficiency that the system can
achieve. Operational efficiency is the actual efficiency after the system has been installed. It is typically less than the
efficiency, due to individual application factors including water hardness, water usage, and other contaminants that
reduce the softener’s capacity.
Performance Claims
Contaminant
Influent
Challenge
Level
Maximum
Allowable Product
Water Level
Barium 10 ±10% mg/L 2.0 mg/L
Radium 226/228 25 pCi/L 5pCi/L
Test parameters include: pH = 7.5±0.5, flow rate = 7.5 gpm
and dynamic pressure = 35±5 psig