Instructions for the installer
26
If the power cable is to be replaced,
the wire section on the new cable must
not be less than 0.75 mm
2
(3 x 0.75
cable), bearing in mind that the end to
be connected to the appliance must
have the earth wire (yellow-green) at
least 20 mm longer.
Use only H05V2V2-F cable or similar which has a maximum temperature of
90°C. Any replacement needed should be carried out by a specialised
technician who should make the mains connections according to the
following diagram.
L = brown
N = blue
= yellow-green
The manufacturer declines all liability for injury to persons or animals
and for damage to property resulting from non-observance of the above
prescriptions or from tampering with any part of the appliance.
2.4 Ventilation requirements
The appliance may be installed only in rooms with permanent ventilation,
as required by standards regulations in force. The room in which the
appliance is installed must have sufficient air flow to satisfy the
requirements of normal gas combustion and of necessary air exchange
in the room. The air intakes, protected by grills, must be appropriately
sized and placed so as not to be blocked in any way.
The room must be suitably ventilated to avoid overheating or excess
humidity produced by cooking; after any prolonged use, a window should
be opened or the speed of any fans should be increased.
2.5 Discharge of combustion products
Discharge of combustion products must be guaranteed by means of
hoods connected to a natural draught flue with certain efficiency, or by
means of forced aspiration. An efficient aspiration system requires
careful planning by a qualified specialist, respecting the positions and
distances prescribed by standards. After installation, the installer must
issue a certificate of conformity.