9 Fasten the connecting studs to the appliance.
Fasten the exhaust air pipe to the connecting
studs and seal appropriately.
Connection with round pipe.
Connection with flat-channel pipe.
Connection with flat-channel pipe on the
underside of the appliance.
Note: If using an aluminum pipe, smooth the
connection area beforehand.
10 Connect the connecting cable. Firmly insert the
control cable from the control unit into the
appliance and the fan module. The plug must
snap into place. Connect the control unit to the
mains and check that it works correctly. If the
appliance does not work: Check that the
connection cable is positioned correctly.
Connect Electrical Supply
Refer to data plate for more information. See "Service"
for data plate location.
The branch-circuit breakers ampacity, the wire sizes
and the connections must be conform to the
requirements of the National Electrical Code or
Canadian Electrical Code and all local codes and
ordinances.
Attach flexible conduit to the junction box. Connect
the lead wires to the junction box supply wires in
proper phase:
black (L1) to black
red (L2) to red
green to ground
The mains connecting cable must at least correspond
to the type SJTO 3x16 AWG 105°C. The mains
connecting cable must only be purchased through and
connected by an authorised specialist.