Faber 630001429 Diamante Isola Push Button

User Manual - Page 5

For 630001429.

PDF File Manual, 17 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Version 08/10 - Page 5
upper
chimney
cover
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
3 3/8” min
15 3/8” max
23
5/8”
3 3/16”
36”
FIGURE 4
DUCTED
DIMENSIONS
x
min & max ceiling height examples
x = 30"
min
8'
3/16"
max
9'
3/16"
x = 28"
min
7'
10 3/16"
max
8'
10 3/16"
x = 26"
min
7'
8 3/16"
max
8'
8 3/16"
x = 24"
min
7'
6 3/16"
max
8'
6 3/16"
The Diamante Isola chimney is highly
adjustable and designed to meet varying
ceiling heights as indicated in FIGURE 4.
The chimney can be adjusted for ceilings
between 7' 6 3/16" and 9' 3/16" depending
on the distance between the bottom of
the hood and the cooktop (distance x in
FIGURE 4).
For higher ceiling installations, the High
Ceiling Chimney Kit includes an additional
support structure which adds 27 1/2" to the
ceiling heights in FIGURE 4.
DUCTED INSTALLATION DIMENSIONS
(vented to the outside)
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless. When installed ductless, the rangehood vents out of a grate on
the back of the lower chimney. Ductless installations require a Ductless Conversion Kit, available from your dealer.
WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILL BE
USED AND CAREFULLY CALCULATE ALL MEASUREMENTS.
WARNING
DUE TO THE SIZE
AND WEIGHT OF THIS
RANGEHOOD, THE
SUPPORT MUST BE
FIRMLY ATTACHED TO
THE CEILING. For plaster
or sheet rock ceilings, the
support must be attached
to the joists. If this is
not possible, a support
structure must be built
behind the plaster or sheet
rock. The manufacturer
assumes no responsibility
for injury or damage caused
by improper installations.
27”
!
11 7/16"
NOTE: To reduce the chimney
structure to the 27" minimum height
as shown, the middle section of the
support structure (FIGURE 5) needs
to be removed. Out of the box, the
minimum chimney length is 32", not
27" as shown in the dimensional
diagram. Add 5" to all minimum
ceiling height calculations if keeping
the middle section in place. Contact
Faber at
508-358-5353 for more information.
FIGURE 5