10 • EN
CHARGING PROGRAMS AND OPTIONS
Press the MODE-button to select between the charging programs and to add charging options. The LEDs will indicate which pro-
grams and options that are selected. The selected program will be memorised and restarted next time the charger is connected.
The table explains the different Charging Programs:
Program Battery Size (Ah) Explanation
1.2–14Ah
Small battery program
14.4V/0.8A. Use for smaller batteries.
14–160Ah
Normal battery program
14.4V/4.3A. Use for WET batteries, Ca/Ca, MF, GEL batteries and many AGM
batteries.
Charging Options
Option Explanation Temp range
AGM
AGM option
Use for charging most AGM batteries like Optima and Odyssey.
-4ºF122ºF
(-20°C–+50°C)
RECOND
Recond option
Use to return energy to the empty WET and Ca/Ca batteries. Recond your battery
once per year and after deep discharge to maximise lifetime and capacity. The Recond
program adds STEP 6 to the normal battery program.