19
GB
G:\_Upload\4082180131\4082180131SDMM81AEP\02GB-SDMM81AEP\01GB02BAS-AEP.fm
masterpage:Right
SDM-M81
4-082-180-13(1)
Trouble symptoms and remedies
If a problem is caused by the connected computer or other equipment, please refer to the connected equipments instruction manual.
Use the self-diagnosis function (page 21) if the following recommendations do not resolve the problem.
Symptom Check these items
No picture
If the 1 (power) indicator is not lit,
or if the 1 (power) indicator will not
light up when the 1 (power) switch
is pressed
Check that the power cord is properly connected.
Check that the monitorspowerison (page 9).
If the 1 (power) indicator is green
or flashing orange
Use the self-diagnosis function (page 21).
If CABLE DISCONNECTED
appears on the screen
Check that the video signal cable is properly connected and all plugs are firmly seated in
their sockets (page 7).
Check that the video input connectors pins are not bent or pushed in.
Check that the input select setting is correct (page 9).
A non-supplied video signal cable is connected. If you connect a non-supplied video
signal cable, CABLE DISCONNECTED may appear on the screen before entering the
power saving mode. This is not a malfunction.
If NO INPUT SIGNAL appears on
the screen, or the 1 (power)
indicator is either orange or
alternating between green and
orange
Check that the video signal cable is properly connected and all plugs are firmly seated in
their sockets (page 7).
Check that the video input connectors pins are not bent or pushed in.
Check that the input select setting is correct (page 9).
Set the digital/analog select switch to an appropriate position according to the type of
signals input via the DVI-I (digital/analog RGB) input connector (page 7).
xProblems caused by the connected computer or other equipment
The computer is in the power saving mode. Try pressing any key on the keyboard or
moving the mouse.
Check that your graphics board is attached to the computer properly.
Check that the computerspowerison.
If OUT OF SCAN RANGE appears
on the screen
xProblems caused by the connected computer or other equipment
Check that the video frequency range is within that specified for the monitor. If you
replaced an old monitor with this monitor, reconnect the old monitor and adjust the
frequency range to the following:
Horizontal frequency: 28 92 kHz, Vertical frequency: 48 85 Hz
If using Windows If you replaced an old monitor with this monitor, reconnect the old monitor and do the
following. Select SONY from the Manufactures list and select SDM-M81 from the
Models list in the Windows device selection screen. If SDM-M81 does not appear in
the Models list, try Plug & Play or install the information file for this monitor using
the Windows Monitor Information Disk (page 9).
If using a Macintosh system Check and refer to the supplied Notes for Macintosh users.
Picture flickers, bounces,
oscillates, or is scrambled
Adjust the pitch and phase (Analog RGB signal only) (page 13).
Isolate and eliminate any potential sources of electric or magnetic fields such as other
monitors, laser printers, electric fans, fluorescent lighting, or televisions.
Move the monitor away from power lines or place a magnetic shield near the monitor.
Try plugging the monitor into a different AC outlet, preferably on a different circuit.
Change the orientation of the display.
xProblems caused by the connected computer or other equipment
Check your graphics board manual for the proper monitor setting.
Confirm that the graphics mode (VESA, Macintosh 19'' Color, etc.) and the frequency of
the input signal are supported by this monitor (Appendix). Even if the frequency is within
the proper range, some graphics boards may have a sync pulse that is too narrow for the
monitor to sync correctly.
Adjust the computers refresh rate (vertical frequency) to obtain the best possible picture.
01GB01COV-AEP.book Page 19 Friday, April 20, 2001 10:55 AM