HARDWARE INSTALLATION
10 9
HARDWARE INSTALLATION
The sensor needs to be fitted to the live feed cable. Sensors are suitable for cables up to
12mm in diameter. You should not force the cable to fit. The sensor should fit loosely around
the cable and there should be no packing used.
Remove a standard 1cm knock out from the meter box. Feed the mini CT sensor lead from
inside the box out through the raw knock out hole. Open and place the mini CT sensor around
the live feed cable 4 (Fig.5).
Mounting the Transmitter
Insert the jack on the end of the mini CT sensor wire into any of the three input sockets on the
waterproof transmitter. The mini CT sensor acts as a current sensor and relays the current
being drawn into the home to the waterproof transmitter. Mount the waterproof transmitter
on the wall next to or above the meter box. This will make it easier to replace the batteries
(although the batteries will last for a long time). If the panel is in a finished area, you may mount
the transmitter inside the meter box. This may reduce transmission distance. Replace the panel
cover(s) when finished installing the mini CT sensors.
INSTALLING THE MINI CT SENSOR
INSTALLING THE MINI CT SENSOR
Fig. 4
Fig. 5
1. Pull the release clip to open the
mini CT sensor (Fig. 4)
2. Select the correct feed cable, and
then place the sensor around it
3. Push the clasp to close around
the feed cable securely (Fig. 5)
Note - Keep your fingers well away from the metal lugs where the main service wires attach to
the breaker, unless you are able to turn off the inbound power from your utility source outside.
Wiring configurations and types of main panels will vary greatly.
Note - If the cables in your meter box are too big for the mini CT sensor you can order XL CT
sensors at www.efergy.com or from your local dealer.
IMPORTANT - Always make safety your first priority, see the relevant Important Safety
Information (page 3). Under no circumstances should you try to attach the sensor if there is
any damage to the meter box cables. No cables need to be cut. Do not cut any cables.
If in doubt, contact an electrician or other qualified person to assist you with the installation of
the mini CT sensor.