WaterAce ‎WA20PLS Irrigation Pump

Owner's Manual - Page 6

For WA20PLS. Series: WAPLS Series
Also, The document are for others WaterAce models: WA10/15PLS

PDF File Manual, 10 pages, Read Online | Download pdf file

WA20PLS photo
Loading ...
Loading ...
Loading ...
6
ELECTRICAL
Disconnect power before working on
pump, motor, pressure switch or wiring
Motor may be hot. Allow to cool 20
minutes.
Water pressure may have built up in
the pump, pipes and/or tank. Drain
water to relieve pressure.
!
!
4. Use wire size specied in Wiring Chart (below). If
possible, connect pump to a separate branch circuit
with no other appliances on it.
5. Do not ground to a gas supply line.
6. Wire motor according to diagram on motor nameplate.
If nameplate diagram diers from diagrams above,
follow nameplate diagram.
7. If this procedure or the wiring diagrams are
confusing, consult a licensed electrician.
NOTICE Pump must be on dedicated circuit
not shared by any other equipment.
Wiring Connections
Risk of electric shock. Electricity
can shock, burn or kill.
1. To avoid dangerous or fatal electrical shock, turn OFF
power to motor before working on electrical
connections.
2. Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or
fatal electrical shock hazard.
3. Supply voltage must be within +/- 10% of nameplate
voltage. Incorrect voltage can cause re or damage
motor and voids warranty. If in doubt consult a
licensed electrician.
Motor Voltage Settings
Motors are designed to run on either 115 volt or 230 volt
current. Be sure the motor’s current is set to match the
current being supplied to your motor from the electrical
source.
To set your motor to the correct voltage, rst remove the
rear cover plate. Next slide the voltage conversion switch
to the correct voltage. WIRING THE PUMP FOR THE
INCORRECT VOLTAGE WILL DAMAGE THE PUMP.
Wiring Chart Recommended Wire and Fuse Sizes for 115 and 230 volts
BRANCH
AWG
DISTANCE IN FEET FROM MOTOR TO SUPPLY
FULL LOAD
FUSE/BREAKER
MIN. WIRE
0-100 101-200 201-300 301-400 401-500
MOTOR HP VOLTS AMPS RATING AMP SIZE (mm
2
) AWG WIRE SIZE (mm
2
)
1 115/230 18.5/9.25 30/15 10/14 (5.5/2) 10/14 (5.5/2) 8/14 (2/2) 6/14 (14/2) 6/12 (14/3) 4/10 (21/5.5)
1-1/2 115/230 22/11 30/15 10/14 (5.5/2) 10/14 (5.5/2) 8/14 (8.4/2) 6/12 (14/3) 4/10 (21/5.5) 4/10 (21/5.5)
2 115/230 27.0/13.5 35/20 8/12 (8.9/3) 8/12 (8.9/3) 8/12 (8.4/3) 6/10 (14/5.5) 4/10 (21/5.5) 4/10 (21/5.5)
Loading ...
Loading ...
Loading ...