MAINTENANCE AND CARE
CLEANING THE FILTER
Clean the lint filter after each use. Remove
by pulling straight up.
To clean the filter wipe with a cloth to
remove any lint which has accumulated.
Allow the filter to dry before reinserting
back into the appliance.
CLEANING THE CABINET AND DRUM
Use a soft damp cloth to wipe the cabinet and drum
Do not directly rinse with water.
Do not use scourers or scrapers
Do not use alcohol, detergent or bleach wipes.
After cleaning the drum, ensure the door is left open to allow the drum to
dry naturaly.
SAFETY CUT OUT
This dryer has a safety cut out which is
activated if the temperature is too high.
If the unit cuts out, leave the appliance for
at least 10 minutes to cool before pressing
the rest button. (press until you hear it click,
you may require a pencil or similar)
The reset button is located on the rear of
the appliance.
The cutout may operate for one of the following reasons which should be
resolved before further use.
The lint filter is blocked
The exhaust outlet on the rear of the dryer is blocked.
Poor ventilation in the room where the dryer is located.