Possible Cause: The rubber drain stopper is not installed.
Solution: Install the rubber drain stopper and drain cover, if applicable. Some models include
multiple drain ports, ensure all ports are covered. Refer to user manual for more information.
Problem: Fan speed cannot be changed
Possible Cause: Fan speed differences are not very noticeable.
Solution: The fan speed difference is not very noticeable when the compressor is on. Try setting
the unit to Fan only mode, you should be able to hear the difference between high and low fan
speed settings.
Problem: The air conditioner needs to be drained frequently
Possible Cause: The ambient humidity may be high.
Solution: Close and insulate any windows and doors to the room. For dual hose models
remove the intake hose if the outside humidity is high or it is raining.
Possible Cause: The self-evaporative feature is not working or there is a loose internal
connection.
Solution: Contact Whynter Customer Support.
Problem: The window slider kit does not fit the window
Possible Cause: The window is smaller than the window slider kit.
Solution: If the window opening is smaller than the minimum length of the window slider kit,
the window slider kit can be cut to fit the window opening. Never cut into the exhaust or intake
hose cut-outs on the window slider kit.
Possible Cause: The window is larger than the window slider kit.
Solution: If the window opening is larger than the maximum length of the window slider kit,