INSTALLATION
Installation
6 | CK 150-1 / 200-2 Trend www.stiebel-eltron-usa.com
11. Installation
DANGER: Electrocution
If installing the appliance in rooms with a bath and/or
shower, take the relevant safety zone into account in
accordance with the information on the appliance type
plate.
Install the appliance in such a way that switching and
control equipment cannot be touched by a person in
the bath or shower.
WARNING: Fire
Only fit the appliance to a vertical wall that is heat-re-
sistant to at least194°F(90°C).
Maintain minimum clearances to adjacent surfaces.
Never install the appliance directly below a wall sock-
et.
11.1 Wall mounting
NOTE:
Secure the wall mounting bracket with the tab cut-out
pointing upwards.
NOTE:
Use appropriate fastening materials.
D0000056453
1
1 Wall mounting bracket
f Mark out the holes to be drilled for the wall mounting brack-
et on the wall. Use the wall mounting bracket as a template
for this purpose.
f Drill the holes.
f Secure the wall mounting bracket horizontally to the wall
with suitable rawl plugs and screws.
NOTE:
The horizontal and vertical slots enable an adjustment
in case the fixing holes are not quite where they
should be.
11.2 Appliance installation
D0000056454
1
1 Wall mounting bracket
f Hook the appliance with the upper vertical recesses of the
back panel onto the wall mounting bracket.
D0000056453
1
2
1 Through-hole for locking screw
2 Locking screw
f Mark out the hole to be drilled for the locking screw. Use the
through hole in the lower section of the appliance casing as a
template for this purpose.
f Remove the appliance from the wall mounting bracket.
f Drill the hole for the locking screw. Insert a suitable rawl
plug.
f Hang the appliance as described on the wall mounting
bracket.
f Secure the appliance with a suitable screw.
11.3 Power supply
WARNING: Electrocution
Carry out all electrical connection and installation
work in accordance with relevant regulations.
!
MATERIAL LOSSES:
The specified voltage must match the mains voltage.
Observe the type plate.