Step 3 - Connect the Battery
Connect the Battery
The generator battery is disconnected on arrival to
prevent discharge or accidental starting in storage and
transportation.
To connect the battery:
a. Remove the battery cover plate using the wrench
from the toolkit.
b. Locate the negative battery cable above and behind
the battery. One side is connected to ground and
the other end needs to be connected to the battery.
Route the free end to the negative battery terminal.
c. Push the black rubber boot up the wire to expose
the connector.
d. Securely connect the free end of the battery cable
to the negative battery terminal using the screw
and nut from the battery with the screwdriver and
wrench from the toolkit.
e. Cover the connected terminal with the black rubber
boot.
f. Reinstall the battery cover plate.