Loading ...
Loading ...
Loading ...
en Installation instructions
30
¡ The appliance must be disconnected from the
power supply whenever installation work is being
carried out.
¡ Contact protection must be ensured during the in-
stallation.
Electrically connecting an appliance without a
protective contact plug
Note:Only a licensed professional may connect the ap-
pliance. Damage caused by incorrect connection is not
covered under the warranty.
An all-pole isolating switch must be integrated into the
permanent electrical installation according to the install-
ation regulations.
1.
Identify the phase and neutral conductors in the
socket.
The appliance may be damaged if it is not connec-
ted correctly.
2.
Connect the hob in accordance with the connection
diagram.
See the rating plate for the voltage.
3.
Connect the wires of the mains power cable accord-
ing to the colour coding:
Green/yellow = Protective conductor
Blue = Neutral conductor
Brown = Phase (external conductor)
18.8 Installing the appliance in a tall unit
1.
Remove the mounting brackets.
The mounting brackets are not required for installing
in a tall unit.
2.
Tighten the screws for the mounting brackets on the
appliance.
3.
Remove the transport locks on the right and left and
then dispose of them.
4.
The appliance must be transported by two people
using the carry handles on the right and left, while
securing the front of the appliance with one hand.
5.
Place the appliance in the unit and, before pushing
it in, fold the carry handles down.
6.
Push the appliance in fully.
Do not kink or trap the connecting cable, or route it
over sharp edges.
7.
Centre the appliance.
There must be an air gap of at least 5mm between
the appliance and adjacent unit fronts.
8.
Use a spirit level to adjust the appliance so that it is
perfectly level.
Loading ...
Loading ...
Loading ...