Search
Home
Bookmarks
Brands
Articles
About us
Home
Pro-Ject
Pro-Ject TUBEBOXDS2SILWAL User Manual
User Manual Pro-Ject TUBEBOXDS2SILWAL Sumiko Tube Box DS2 Silver/Walnut Tube Phono-Preamplifier
Documents for Pro-Ject TUBEBOXDS2SILWAL
The following documents are available:
User Manual
User Manual - (English)
Read Online
|
Download pdf
Other Documents
Product Information - (English)
Download
Photos
Photos:
View Photos
User Manual
For TUBEBOXDS2SILWAL.
Page 1/6
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Contents
Table of Contents
Search
Previous
Next
Bookmarks
INSTRUCTI
ONS FOR USE
Pro-
Ject Tube Box
DS
2
Loading ...
Loading ...
Loading ...
1
2
3
4
5
6
>
Summary of Contents for Pro-Ject TUBEBOXDS2SILWAL:
Warning of a hazard for the user, the unit or possible misuse
2
Important notice
2
Connectors
2
Do not connect the phono amplifiers output to a phono input (sometimes labelled gram, disc or RIAA) on the amplifier.
2
Connecting one or two record players
2
Connection to the amplifier
2
Mains power connection
3
Remote power on - triggers
3
Controls
3
To switch on from standby or to standby
3
Settings
3
Input and Output
3
Tube Box DS2 has two separate inputs IN1, IN2 and outputs OUT1, OUT2. The button Input selects between inputs and the button Output switches between outputs.
3
Subsonic
3
Turn on and off subsonic filter. Any change will be automatically stored for the chosen input, when input is changed or the unit is switched into standby mode.
3
Adapt to connected phono cartridge
3
The rotary control and the 3 control buttons on the right side of the front panel are used to set gain, input impedance, input capacitance. You will find all details about construction principle and technical data in the manual of the phono cartridge....
3
Gain dB
4
Gain for the outputs can be set between 40dB, 45dB, 50dB, 60dB and 65dB in steps of 5dB or 10dB. Any change will be automatically stored for the chosen input, when input is changed or the unit is switched into standby mode.
4
Input impedance, variable â low-output MC cartridges
4
The button Loading Ω must be set to Variable. Use the rotary controller to set input impedance to desired value (10Ω-1000Ω)
4
* Input capacitance is irrelevant for low-output MC cartridges
4
Input impedance, 47k - high-output MC and MM cartridges
4
Input capacitance, variable â high-output MC and MM cartridges
4
The rotary control must be set to 10 Ω. Press Loading Ω until the LED marked by 47k lights up. The device has a basic capacity of 47pF, and the Load pF button can be used to increase the terminating capacity by 100pF, 220pF or 320pF depending on the L...
4
Examples of typical settings
4
Technical specifications Pro-Ject Tube Box DS2
5
Potential incorrect use and fault conditions
6
Service
6
Warranty
6
Copyright, trademarks
6
File type: PDF
File name: 14498441_tubeboxds2silwal.pdf
File size: 247.54 KB
File Language: English
Pages: 6
Author: Pro-Ject
File created: 2017-02-14
Published: 2021-05-18
Updated: 2023-07-13
Download File
Specifications
Brand:
Pro-Ject
Model: TUBEBOXDS2SILWAL
Category:
Audio
View in the file:
Full Specifications
See other models:
PHONOBOXMM
PHONOBOXS2SIL
Photos
Download User Manual
Related Products
Nobsound 769700919653
McIntosh C22MK V
Teac TN280BTA3WA
Pro-Ject PRO-PHOBOXE-BLA
McIntosh C12000ST
MoFi ULTRAPHONO
McIntosh C8
McIntosh C49
IPower 400 WATT HPS DIGITAL DIMMABLE
Insignia IS-TV040920
KitchenAid 5KSB8270AMS
Sony XDP-4000X
Smeg DW45QXSA
Pro-Ject PHONOBOXS2SIL
Pro-Ject PHONOBOXMM
Table of Contents
×
Warning of a hazard for the user, the unit or possible misuse
2
Important notice
2
Connectors
2
Do not connect the phono amplifiers output to a phono input (sometimes labelled gram, disc or RIAA) on the amplifier.
2
Connecting one or two record players
2
Connection to the amplifier
2
Mains power connection
3
Remote power on - triggers
3
Controls
3
To switch on from standby or to standby
3
Settings
3
Input and Output
3
Tube Box DS2 has two separate inputs IN1, IN2 and outputs OUT1, OUT2. The button Input selects between inputs and the button Output switches between outputs.
3
Subsonic
3
Turn on and off subsonic filter. Any change will be automatically stored for the chosen input, when input is changed or the unit is switched into standby mode.
3
Adapt to connected phono cartridge
3
The rotary control and the 3 control buttons on the right side of the front panel are used to set gain, input impedance, input capacitance. You will find all details about construction principle and technical data in the manual of the phono cartridge....
3
Gain dB
4
Gain for the outputs can be set between 40dB, 45dB, 50dB, 60dB and 65dB in steps of 5dB or 10dB. Any change will be automatically stored for the chosen input, when input is changed or the unit is switched into standby mode.
4
Input impedance, variable â low-output MC cartridges
4
The button Loading Ω must be set to Variable. Use the rotary controller to set input impedance to desired value (10Ω-1000Ω)
4
* Input capacitance is irrelevant for low-output MC cartridges
4
Input impedance, 47k - high-output MC and MM cartridges
4
Input capacitance, variable â high-output MC and MM cartridges
4
The rotary control must be set to 10 Ω. Press Loading Ω until the LED marked by 47k lights up. The device has a basic capacity of 47pF, and the Load pF button can be used to increase the terminating capacity by 100pF, 220pF or 320pF depending on the L...
4
Examples of typical settings
4
Technical specifications Pro-Ject Tube Box DS2
5
Potential incorrect use and fault conditions
6
Service
6
Warranty
6
Copyright, trademarks
6
Search:
×
Search