14
WATER CONDENSATION DRAINAGE (CONTINUED)
EN
Unplug the unit from power source.
Remove the upper rubber drain plug.
Some residual water may spill so please have a pan to
collect the water. See diagram.
Connect the drain connector to a ¾" Hose or standard
garden Hose (not included).
The water can be continuously drained through the
drain tube into a floor drain or bucket.
Replace the drain plug.
You can now turn on the unit.
1.
2.
3.
4.
5.
6.
Continuous Draining for Dehumidifier Mode
Drain Tube
Upper Rubber
Drain Plug
While using the unit in dehumidifier mode, continuous
drainage is recommended.
IMPORTANT: The water cannot be drained using the continuous drain option in heating* mode.
In Heating mode, the internal water tank collects condensation faster and may require more
frequent emptying of the tank in more humid rooms. It is recommended to use the heating mode in a
room with 50 % humidity or lower. Avoid operating moisture-creating products or appliances such as
a humidifier or a kettle when using the unit in heating mode.
IMPORTANT: It is NOT recommended to connect the drain Hose for continuous drainage while the
unit is switched ON in air conditioning cooling mode. Doing so can reduce the cooling efficiency
of the Portable Air Conditioner. Only drain the water condensation when the unit is switched off.
Continuous drainage is only suitable when the unit is set up in Dehumidifier mode.