VENTILATION REQUIREMENTS
WALL INSTALLATION
ISLAND INSTALLATION
Non-combustible Non-combustibleCombustible Combustible
z
Ventilation hoods and blowers are designed for use with single wall ducting, however some local building codes or inspectors may require double wall ducting and/or a damper. Consultlocal
building codes and/or agencies, before installing to ensure local requirements are met. Semi-rigid ducting is recommended for maximum effectiveness.
z
Hood blower speeds should be variable to reduce noise and loss of household air.
z
Due to a high volume of ventilation air, a source of make-up air (outside replacement air) is recommended. This is particularly important for tightly sealed and insulated homes. A reputable
heating and ventilating contractor should be consulted.
C C
C C
A A
B B
VENTILATION UNIT WALL INSTALLATION RECOMMENDATIONS
Hood
A min. 30" (762mm) max. 42 (762mm)
B min. 36" (914mm) max. 42 (762mm)
C min. 19" (480mm)
Blower
30" Cooktop min. 550 CFM
36" Cooktop min. 550 CFM
VENTILATION UNIT ISLAND INSTALLATION RECOMMENDATIONS
Hood
A min. 30" (762mm) max. 42 (762mm)
B min. 36" (914mm) max. 42 (762mm)
C min. 19" (480mm)
Blower
30" Cooktop min. 550 CFM
36" Cooktop min. 550 CFM