8 49-7794 Rev. 1
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT – Save these
instructions for local inspector’s use.
IMPORTANT – Observe all
governing codes and ordinances.
Note to Installer ±%HVXUHWROHDYHWKHVH
instructions with the Consumer.
Note to Consumer ±.HHSWKHVHLQVWUXFWLRQV
for future reference.
Skill level ±,QVWDOODWLRQRIWKLVDSSOLDQFH
requires basic mechanical skills.
• Completion time ±$SSUR[LPDWHO\KRXU
We recommend that two people install this
product.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is
not covered under the Warranty.
 <RX0867XVHDOOVXSSOLHGSDUWVDQGXVH
proper installation procedures as described
in these instructions when installing this air
conditioner.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
Installation Instructions
INSTALLATION INSTRUCTIONS
TOOLS YOU WILL NEED
Phillips head screwdriver
Ruler or tape measure
Pencil
Level
Scissors or knife
Flat-blade screwdriver
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case.
The device should be tested on a periodic basis by
first pressing the TEST button and then the RESET
button while plugged into the outlet. If the TEST
button does not trip or if the RESET button will not
stay engaged, discontinue use of the air conditioner
and contact a qualified service technician.
6RPHPRGHOVUHTXLUHDYROW
AC,60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes
the possibility of electric shock hazard. If
the wall outlet you plan to use is only a
2-prong outlet, it is your responsibility to
have it replaced with a properly grounded
3-prong wall outlet.
6RPHPRGHOVUHTXLUHYROW$&
protected with a time-delay fuse or circuit
breaker. These models should be installed
on their own single branch circuit for best
performance and to prevent overloading
house or apartment wiring circuits, which
could cause a possible fire hazard from
overheating wires.
CAUTION
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord of this
air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
ELECTRICAL
REQUIREMENTS
$GMXVWDEOHZUHQFK
If the sill support bolts do not
contact the window sill, or if
you have a window without a sill, you must
order accessory kit RAK87 to properly install
this air conditioner. Call 877.959.8688 or visit
GEApplianceparts.com.