User manual Dehumidifier
To prevent any internal damage, it is very important to keep refrigeration units (like this one) upright throughout their journey. Please leave it standing upright and outside the box for 24 HOURS before plugging it in.
For your safety, please read the manual carefully and and keep the manual to serve as a reference for product usage. This product is for home use only. Please use this product according to the installation and operation of this manual.

Front

Rear



Mode Setting
There are Dry Clothes Mode, Dehumidify Mode, Continuous Dehumidify Mode.
When Power On, press the [Mode] button, the device will cycle through the drying, dehumidifying, and continuous dehumidify modes.
Each time you press the mode button, the working mode will switch accordingly.
Dry Clothes Mode: Humidity and fan speed cannot be set.
Dehumidify Mode: Humidity and fan speed can be set.
Continuous Dehumidify Mode: Humidity cannot be set,fan speed can be set.
Humidity Setting
The humidity level can be set within a range of 30%RH to 80%RH in 5% increments.
Timer Setting
This setting is used for you to be able to set a time when you can set the timer to turn off and on the machine automatically.
Timer Setting
This setting is used for you to be able to set a time when you can set the timer to turn off and on the machine automatically.
Speed Button
Controls the fan speed.Press to select either High or Low fan speed. Higher fan speed will result in quicker moisture removal. Set the fan controlto High for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred, set the fan control to Low.
Light Function Settings
Power Off Memory Function
Overflow Protection
When the bucket full of water, the machine will turn off automatically.The indicator light
will flash. After you empty the water from the bucket the indicator light
will turn off. The machine will restart to work.
Auto Defrost Function
When the dehumidifier is running at a lower temperature, the system will automatically determine whether there is a presence of frost. If the machine determines there is a presence of a frost, it will defrost automatically.
Defrost Action
The fan runs at high wind speed when the compressor stops.
Defrost Status Display
On defrosting status, power button"o" is flashing.
":lf you set the unit to high speed fan mode, it indicator will light up.
" If you set the unit on low speed fan mode, it indicator will light up.
" : When dry clothes mode is selected, it will be on, otherwise it will be off.
": When the device starts to dehumidify, the indicator light will on. When the room environment humidity is reach the setting humidity,the light will be flashing. Otherwise it will be off.
": when continuous dehumidification mode is selected, it will be on, otherwise it will be off.
: When the water tank or bucket is full, this indicatorwill be flashing.The dehumidifier can be used for drying clothes in rainy weather.
Step 1.
Hang the washed clothes in a small space such as cloakroom, bathroom, or storage room.
Note: Keep away the unit from the water drip from the washed clothes.
Step 2.
Open the dehumidifier and set the humidity level at 30%RH. It is best if you let the air outlet of the dehumidifier to blow air to the clothes directly.

Attention
When the machine signals the alarm, it will flash or display the alarm, in case there are multiple error on the unit, it will show the error in a turn display behavior.
Note: Before starting the machine, please ensure that the air outlet has been opened, otherwise the machine will overheat. Do not pull out the power cord directly to stop the machine.
There are two ways to remove collected water.
Use the Bucket
When the water tank is already full, the Full Tank Alert indicator will light up, the dehumidifier will automatically shut down until the tank has been emptied and placed back to the unit.
Ways to Empty the Water Tank


Note:
Do not remove the float from the watertank. If the float in the watertank is removed, the sensor may not be able to determine the water level stored in the tank properly that may lead to water overflow leak from the water tank.
If the watertank is dirty, just use cold water or warm water to clean it. Do not use detergent, steel wool, chemically treated dust cloth, gasoline, benzene, thinner or other solvents. Otherwise, it may damage the watertank and cause it to leak.
When placing back the water tank, use your hands to press the tank back in its place. If the water tank is not placed properly, sensors or protections from water overflow may not operate as expected.

7. Continuous Drainage
Remove the power supply, take out the water tank, open the drain cover, insert the water pipe into the continuous drain port and push it back into the water tank. Connect the power supply to start the operation. The water outlet of the water pipe should be lower than the continuous drainage port by more than 3.9inches, and the water pipe cannot be bent.


WARNING: Turn the dehumidifier off and remove the plug from the wall outlet before cleaning.
A- Cleaning the dehumidifier body
Please use only a soft and a bit wet textile or cloth to clean it.
B- Cleaning filter
Slowly insert the filter back into the fuselage.

C-Dehumidifier storage
When you want to store the dehumidifier because you don't use it for a long time. Please pay attention to the following steps:
Check the information below for troubleshooting steps that will save you time to resolve issues that may happen with the unit. The list includes most common issues. Listed below are not result of defective unit, crafts or materials in the unit. If all troubleshooting steps has been exhausted and issue is still occurring, feel free to get in touch with Kesnos Customer Service to get further assistance.
Problem | Reason | Method |
Dehumidifier does not work | The power cord is unplugged. | Make sure that the unit's plug is inserted properly into the power outlet. |
Is the TankFull indicator blinking? (The tank is full or in a wrong position.) | Empty the water in the water tank and then reposition the tank. | |
Is the room temperature above 95°F (35°C)or below41°F (5°C). | This product does not apply to over hot or cold environment, the machine will automatically protection, it is a normal phenomenon. | |
Is the room temperature between 41 °F(5°C) and 68°F(20°C) ? | When running under lower ambient temperature,the machine will automatically defrost, it is a normal phenomenon.Wait until the defrost process finish, it will restart dehumidifying again. | |
The dehumidifier is in the defrosting process. | It is normal the compressor ceases while defrosting process.Wait until the defrost process finish, it will restart dehumidifying again. | |
Does the room humidity is lower than or reach the preset humidity level? (The room humidity has reached the preset humidity level,the dehumidifier enters into Standby Mode and the the LCD and indicators will flashing.) | Please set the humidity 5% decrease by degrees than the room humidity or set the humidity to 30%. | |
There is prevent frequent start function in the machine. Dose the machine stop working just now? | Please wait for more than 3 minutes. | |
Room humidity is low. | The dehumidifier is designed to work in the humidity range of 30%-80%.Above or below the work humidity range, it will not work. |
Dehumidifier does not dry the air as it should | The air filter is dirty. | Clean the air filter. |
Is the air inlet or air outlet obstructed? | Remove the obstruction from the air inlet or outlet. | |
The dehumidifier size is too small for application. | Increase the quantity of dehumidifier. Or change a higher capacity dehumidifier. | |
Poor air circulation. | Please leave about 7.9inch(20cm) around the product. | |
Did not allow enough time to remove the moisture. | Allow enough time to remove the moisture. When first installed, allow at least 3-4 days to maintain the desired RH. | |
The room has not been sealed properly. | Check that all doors, windows and other openings are securely closed. | |
Room temperature is too low, or below41°F (5°C)(The machine will not work and or poor dehumidify efficiency in low temperature) | Please wait the temperature rises above 5°C or higher. | |
The dehumidifier makes loud noise when operating | The dehumidifier is not positioned level. | Move the machine to a horizontal position. |
Is there blocking around the air inlet? The air filter is clogged. | Clean up the dirty form the on the air outlet and intake. | |
Is the filter installed correctly? | Please check whether the filter packing bag removed and install correctly. | |
Dehumidifier operates continuously | Check if the dehumidifier is in CONTINUOUS MODE. | Don’t set the humidity too low. Typically, 40-50% are good settings to use. |
Room humidity is too high. | Change humidity settings. Or change a higher capacity dehumidifier. | |
Doors and windows are open. | Ensure that all doors, windows and other openings are closed. |
Overflow of water on floor | Hose to connector or hose connection may be loose. | Connect the hose with the drain outlet tightly. |
The water bucket has not been installed properly. | Re-install the water bucket properly. | |
The water tank's float been has stunk. | Move the float and let it can be swang freely. | |
The magnet on the float has come off. | Put the magnet in right position. |