ENGLISH
Installation Manual
9
Electrical Connections
DANGER
Disconnect power before servicing the product.
Failure to do so could result in death or
electrical shock.
General information
WARNING
x The models may be powered at 240V or 208V.
This cooktop does not require a neutral connection. If
the cooktop is to be completely enclosed in a cabinet,
feed the cooktop cable through the opening in the
cabinet. Make the electrical connection following the
appropriate steps for your installation.
Your cooktop must be connected to the proper
electrical voltage and frequency as specified in the
table on the right.
Connect with copper wire only
If the house has aluminum wiring, follow the
procedure below:
1. Connect the aluminum wiring to the copper wire
by using special connectors designed and
Underwriters Laboratories-listed for joining copper
to aluminum. Follow the electrical connector
manufacturer's recommended procedure.
2. Aluminum/copper connection must conform with
local codes and industry- accepted wiring
practices.
The flexible conduit (supplied) 3 feet long (100 cm)
located at the right rear of the cooktop bottom box
should be connected directly to junction box. Do not
cut the conduit. A U.L - or CSA - listed conduit
connector must be provided at each end of the power
supply cable (at the cooktop and at the junction box.)
A time delay fuse or circuit breaker is recommended.
Do not ground to a gas pipe. Do not have a fuse in the
grounding or neutral circuit.
Fuse both supply (phase) lines.
WARNING
Improper connection of aluminum house wiring to
the copper leads can result in a serious problem.
National Fire Protection Association
Batter/march Park Quincy, Massachusetts 02269
A three-wire, single phase, 240 Volt 60 cycle electrical
system (properly circuit protected to meet Local
Codes of NFPA No.70) must be provided. Unit must
be properly grounded in accordance with local wiring
code. The chart below recommends the minimum
circuit protector and wire size if the appliance is the
only unit on the circuit. If smaller sizes of wire are
used, the unit efficiency will be reduced and a fire
hazard may be created. It is advisable that the
electrical wiring and hookup be accomplished by a
competent electrician.
SERIAL TAG
Model
Power Supply
240 V 60 Hz 208 V 60 Hz
Approval
code
30"
ECCB330H1ASS
6,7kW 28A 5,03kW 24A
514T40IA
ECCB330H1ABL
514T40NA
36"
ECCB336H1ASS
9,4kW 39A 7,06kW 34A
514V50IC
ECCB336H1ABL
514V50NC
Figure 12. Location of serial tag
Model
Power Supply
 
Approval
code
24”

6,0kW 25A 4,5Kw 21,5A 514Y40NN
6,1kW 25,5A 4,6Kw 22A 514Y40IL
30” 6,7kW 28A 5,03kW 24A
514T40IA
514T40NA
36” 9,4kW 39A 7,06kW 34A
514V50IC
514V50NC
F3RK24**
F3RK30**
F3RK36**