Owners Manual - RADS-183P, 253P, RAD-283M, REG-183M, 253M
6
6
INSTALLATION INSTRUCTIONS
10. Your unit may come with internal packaging.
This packaging must be removed prior to
installing the air conditioner back into the
cabinet.(see Fig.7).
2
Install Top Angle and
Side Bracket
1. Attach foam gasket to top angle
above holes as shown in Fig.6.
2.Install top angle and side retainers
to cabinet as shown in Fig.8 (10 sc-
rews).
3
Assemble Window Filler Panels
1.Place cabinet on floor, a bench, or
a table.
2.Slide I section of window filler panel
into side retainer on the side of the
cabinet (see Fig.9 & Fig.10).
Do both sides.
,,
,,
Plastic
Frame
Window Filler
Panel
Side Retainer
Fig.9
5 16 long
hex-head
/
Shipping Packaging
Plastic tie
Fig.7
Fig.8
3.Insert top and bottom legs of window
filler panel frame into channel in the
top angle and bottom rail. Do both
sides.
4.Insert washer head locking 7/16" screws
(2)into holes in top leg of filler panel
frame (see step 6). Do not totally tigh-
ten. Allow leg to slide freely. Screws
will be tightened after section 6.
4
Place Cabinet in
1.Open window and mark center of window stool as
shown(Fig.11).
2. Place cabinet in window with bottom stool angle
firmly seated over window stool as shown. Bring
window down temporarily behind top angle to
hold cabinet in place(Fig.12).
Stool
Stool
Angle
Top
View
Air Conditioner
Cabinet
Plastic
Frame
"¢" Section
Window
Filler
Panel
Locking
Screw
Hole
Fig.10
Fig.11
Fig.12
3. Shift cabinet left or right as needed to line up
center of cabinet on center line marked on stool.
4. Fasten cabinet to window stool with 2 screws
into holes(You may wish to pre-drill pilot holes).
5. Add bottom rail seal over screws to window stool.