6
INSTALLATION INSTRUCTIONS
1. Route the electrical supply wire from the circuit breaker to the wall thermostat. At the wall can
of heater #1, attach two sets of electrical supply wires with two cable clamp connectors (not
included), leaving a minimum of 6 inches wire lead. One set of electrical supply wire goes to the
wall thermostat and the other set goes to heater #2 (See Figure 7).
2. There are two supply ground wires in the wall can of heater #1. You’ll need to add a small piece of
copper wire (not included) to make the 3-wire connection with the ground screw (See Figure 7).
3. For heater #1, connect each heater wire to one of the supply wires going to the thermostat, and
to one of the supply wires going to the heater #2. Both wires from heater #1 must have a 3-wire
connection.
1. The heater must be properly
installed before it is used.
2. Do not operate without grill.
3. Do not tamper with the high-
temperature safety shutoff.
How to operate your heater
The room temperature is controlled by a thermostat located either on the wall, or on the heater.
Once installation is complete and power is on, follow the steps below for your thermostat.
If you have a wall or built-in thermostat:
1. Turn the thermostat knob all the way to the right.
2. When the room reaches your comfort level, turn the knob to the left, just until it clicks and
the heater turns off. The heater will automatically keep the room temperature around this setting.
3. To reduce the room temperature, turn the knob to the left. To increase the room
temperature, turn the knob to the right.
If you have an electronic wall thermostat, follow the instructions in the programming and operating
guide included with your thermostat.
PLEASE NOTE: On initial start-up, the heater may cause an odor due to the manufacturing
process. It typically goes away within several hours.
OPERATING INSTRUCTIONS
MULTIPLE HEATERS WITH ONE THERMOSTAT (MODEL CS ONLY)
4. For heater #2, make the connections in the wall can as shown in Figure 7 above.
5. Turn power back on at the main disconnect panel.
6. Proceed to OPERATING INSTRUCTIONS.
Figure 7
More than one heater can be wired in parallel on the same circuit breaker (be sure to check national
and local codes for safety requirements). Additional electrical supply wire and cable clamp connectors
are required, and you’ll need to use a wall thermostat. When wiring multiple heaters to one
thermostat, the heaters must be in the same room and be spaced a minimum of three feet apart.
The maximum amperage load you can put on one circuit breaker is limited to either 80% of the circuit
breaker capacity, or the maximum amperage rating of the thermostat, whichever is lower.
heater #2
heater #1
This set of wires
goes to the wall
thermostat
additional ground wire is used here to make the 3-wire connection
This set of wires goes
to heater #2
back of heater
assembly
wall
can
back of heater
assembly
wall can