Installation Clearances
A. 18" (45.7 cm) minimum clearance - upper cabinet to countertop
B. 24" (61.0 cm) minimum - bottom of range hood to cooking surface
C. 30" (76.2 cm) minimum cabinet opening width for 30" (76.2 cm)
models
36" (91.4 cm) minimum cabinet opening width for 36" (91.4 cm)
models
D. 12" (30.5 cm) minimum cabinet depth
E. 36" (91.4 cm) base cabinet height
Venting Requirements
This range hood is factory set to exhaust the air to
the outside through the wall or the roof. A non-vented
(recirculating) installation will require a Charcoal Filter Kit.
See the “Accessories” section for ordering information.
Vent system must terminate to the outdoors, except for
nonvented (recirculating) installations.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use a 7" (17.8 cm) round metal vent or a
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) rectangular metal vent,
depending on your installation requirements. Rigid metal
vent is recommended. Plastic or metal foil vent is not
recommended.
The length of vent system and number of elbows should be
kept to a minimum to provide efcient performance.
For the most efcient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight vent
between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps or duct tape to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has
a damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening around
the cap.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air ow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specied CFM of
air movement. The specied CFM varies from locale to locale.
Consult your HVAC professional for specic requirements in your
area.
Venting Methods
Vent system can terminate either through the roof or wall. Use
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) rectangular with a maximum vent
length of 35 ft (10.7 m) or 7" (17.8 cm) or larger round vent with
a maximum length of 50 ft (15.2 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates
both back pressure and air turbulence that greatly reduce
performance.
A. 7" (17.8 cm) round vent through roof or
3
1
4
" x 10" (8.3 cm x 25.4 cm) rectangular vent
through the roof or wall (purchased separately)
B. Roof/Wall cap with damper (purchased separately)
C. 24" (61.0 cm) minimum above the cooking surface
D. Charcoal Filter Kit (purchased separately)
E. Recirculating grid
C
A
B
D
E
Roof Venting Wall Venting Recirculating
B
A
C
B
A
C
C
D
E