BN-LINK ‎BND-60/U47 25 Hour Mechanical Outlet Timer

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Other Documents

User Manual 24-Hour Mechanical Mini Timer

Product View

1. Clock Dial:

  • Black Part=12PM-12AM Hours.
  • White Part=12AM-12PM Hours.

2. Arrow:

  • Indicates the current time of day.

3. Slide Switch:

  • Slide the switch up to “ON” position
  • Slide the switch down to “” position

4. Push Pins:

  • Each pin represents 30 minutes.
  • Pins down = ON; Pins up = OFF.

5. Socket:

  • Only intended to be used with a grounded device. sition; position.

RATINGS

1. Rated Voltage:

125V, 60Hz

2. Max.Loading:

  • 185W, 15A Resistive, 8A Tungsten.
  • 1/2HP, V-5

WARNINGS

  • Electrical shock hazard
  • Use a grounded outlet
  • Follow local electrical codes
  • For indoor use only
  • Keep children away
  • Unplug timer before cleaning
  • Fully insert plug
  • Do not use in wet locations
  • Do not exceed electrical ratings

APPLICATIONS

  • Lighting
  • TV
  • Humidifiers
  • Nebulizers
  • Automates fans
  • Indoor sprinklers
  • Aquariums
  • Ventilators

OPERATING INSTRUCTION

Step 1. Pull all black pins to upper position

The pins are in down position when taken out of Package.

Step 2. Set a period of time for the unit to be “ON”

  • Locate the black pins and push them down at the marked times when the attached devices is to be "on". Each pin represents a 30-minute time interval.
  • Make sure all pins are in the upper position before beginning.
  • Example: “ON" time is 8:00PM. “OFF” time is 12:30AM. Push down all of the pins between 9:00PM and 12:30AM.
  • Pins are black slices around the dial.

Step 3. Set the “CURRENT TIME”

  • Rotate the entire black push-pin dial clockwise until the arrow aligns with the current time of day on the dial rotate the the arrow aligns 4PM on the dial.
  • Example: It is 4:00pm, please rotate the dial clockwise until the arrow aligns 4PM on the dial.
  • Please pay attention to AM/PM.

Step 4. Set “BYPASS SWITCH”

When the switch is in the “” position, the unit will automatically turn your attached device ON and OFF according to the programmed time. When the switch is in the “ON” position. the unit will bypass the programming and your attached device will remain ON.

Step 5. Plug the unit into an electrical outlet

The unit will rest against the outlet.

Step 6. Attach one device to the unit

Plug a device into the outlet in the front of the unit. Make sure the attached device is switched ON.

HELPFUL TIPS

  1. This timer repeats the same settings daily.
  2. To push down or pull up the black pins. use your finger or the tip of a small instrument such as a pen or pencil.
  3. You can set up to 24 different “ON’ and “OFF” times in a 24-hour period. Pins pressed down represent the ON’ time. pins in the up position represent the “OFF” time.
  4. Switching the unit to “ON’ will bypass programming. however. the timer dial will continue to rotate and maintain the current time.
  5. Unit will stop operating if the power goes out. Once power is resumed. reset the time of day as explained in Step 2 of the instructions.

TROUBLESHOOTING PROBLEM

1. Appliances do not turn on as programmed

  • POSSIBLE CAUSE: Connected appliances are not in “ON” position; they are not functioning; timer is not receiving power, or “BYPASS SWITCH’ is in the “ON” position.
  • CORRECTIVE ACTION: Ensure the connected appliances are functional by plugging them directly into the outlet. Be sure the connected appliances are in the "ON" position if they have their own switch. Make sure the power outlet which the timer is plugged into is active. Check that the “BYPASS SWITCH’ is in the "" position.

2. Appliances come on before the actual time

  • POSSIBLE CAUSE: “CURRENT TIME" was not set properly.
    • CORRECTIVE ACTION: Refer to step 2 of this manual. Be sure “CURRENT TIME" is set in the white section on the timer dial if the “CURRENT TIME" is in the “AM." The “CURRENT TIME" should be set in the black section on the timer dial if the “CURRENT TIME" is in the “PM.”

3. The pins can not be pushed down

POSSIBLE CAUSE:

  1. The pins are already in DOWN’ position
  2. The pins are blocked by the inner mechanism of the slide switch.

CORRECTIVE ACTION:

  1. Pull all pins up with a pen or a similar tool before setting operation.
  2. Slide the switch to ON’ position.

Customer Service Contact

CENTURY PRODUCTS INC.
3545 Granada Ave El Monte Ca 91731
Custom Service Assistance: 1.909.592.1881
E-mail: [email protected]
Http://www.bn-link.com
Hours: 9AM - 5PM PST, Mon - Fri
Designed in California Made in China

Reference file: BN-LINK ‎BND-60/U47 25 Hour Mechanical Outlet Timer