21
If the hob has to adapted to use a different type of gas, the injectors have to be replaced.
If the replacement injectors are not supplied, the
y can be obtained from our Service Centres.
For selection of the appropriate injectors, refer to the injectors table.
Injectors are identified by the diameter, in hundredths of a mm, embossed on their bodies.
Changing the injectors
Remove the grids and b
urner cap from the hob
Use a spanner to replace the injectors "J" (fig. 12) with those suitable for the gas to be used.
Reassemble the burners.
Burners do not require adjustment of the primary air flow.
Adjusting the minimum air flow
After changing the injectors, light the burner and pull off the knob. Bring the valve to the minimum
setting and fit a screwdriver into the rod: screw in to reduce the flame or unscrew to increase it. (fig.
12)
For G30/G31 gas, screw the regulator screw fully in.
In all ca
ses, the required result is a small, even flame right around the burner.
Also check that when the knob is turned quickly from the maximum to the minimum setting, the
burner does not go out. In case of burners with safety valve, check that the flame is just touching the
thermocouple. To check that the setting is correct, leave the burner on for a few minutes. If it goes
out, increase the minimum setting.
ELECTRIC PLATES
NEVER cook food straight on the electric plates;
always use pans or other containers
Turning on the plate
To turn on the electric plate, turn the knob to the setting required.
The numbers from 1 to 6 or from 1 to 11 (fig. 6), depending on whether the hob is fitted with selector
switch or self-adjusting power regulator, indicate the operating positions, with temperature rising (see
table on page 22).
A pilot light on the control panel indicates that the electric plate is in operation.
Using the electric plate
Once the contents of the pan have come to the boil, adjust the power to the heating level required,
bearing in mind that the plate will keep on emitting heat for a few minutes after it is switched off.
Loading ...