All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P,
CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings.
External Control Devices
EXIT (2 Terminals)
This input is a soft open command (maintained switch does not override
external safeties and does not reset alarm condition). Used for exit probe,
telephone entry, external exit loop detector, or any device that would
command the gate/door to open.
l Opens a closing gate/door and holds open an open gate/door, if
maintained, pauses Timer-to-Close at OPEN limit.
SHADOW (2 Terminals)
This input is used for external shadow loop detector when loop is
positioned under the swing of the gate/door.
l Holds open gate/door at open limit
l Only active when the gate/door is at the OPEN limit, disregarded at all
other times
l Pauses Timer-to-Close at OPEN limit
INTERRUPT (2 Terminals)
This input is used for photoelectric sensors and external interrupt loop
detector when loop is on the outside of the gate/door.
l Holds open gate/door at open limit
l Stops and reverses a closing gate/door to open limit
l Pauses Timer-to-Close at OPEN limit, activates quick close and anti-
tailgate features when enabled on the expansion board
OU
T
Interr
u
pt
L
oo
p
OUT
E
xi
t
L
oop
IN
S
h
a
do
w
Lo
op
Com
Com
Com
Exit
Shadow
Control Board
Interrupt
OUT
I
nterr
up
t
L
o
o
p
O
U
T
E
x
it
L
o
o
p
IN
S
ha
do
w
L
oop
External Reset Button
The externally located reset button serves several functions:
l Press the reset button to stop a moving gate/door during a normal
open/close cycle, like a stop button.
l Press the reset button once while the gate/door is in open position to
disable the Timer-to-Close. The gate/door will stay in the open
position. To restart the Timer-to-Close either press the reset button
or activate the gate/door with a programmed remote control.
l Press the reset button to shut off the alarm and reset the operator.
WIRING
l
STOP and COM: Stops a moving gate/door. Hard stop (maintained
switch overrides Open and Close commands and resets alarm
condition). Cancels/resets Timer-to-Close at OPEN limit. Overrides
Open and Close commands (within line-of-sight)
Com
Main Control Board
Stop
RESET
RESET
ACCESSORY WIRING