14
36” DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
4. Remove the internal (8) and external (9) nozzles
and replace them with the LPG nozzles (see
"LPG nozzles table (Pressure in W.C.P.: 10”)").
5. Refit the burner components following the above
instructions in reverse.
Correct burners placement
Pay attention to place the burners in their correct
zones prior to remounting them
.
1. 18000 BTU brass coated burners - to be placed
in the front left and front right zones.
2. 12000 BTU black coated burners - to be placed
in all the other zones.
Refitting the burners
In order to be installed correctly, the shape of the
burner skirt openings must match the shape of the
openings in the burner base.
The flame-spreader crown must be centered on the
burner skirt.
The burner cover must be leveled and centered with
respect to the burner skirt.
Each burner component must be positioned horizon-
tally and must correctly interlock with each other.
Check that they are fitted correctly by moving each
component gently. If the components do not fit cor-
rectly or are inclined, adjust the position of each
component until it remains fixed in position.
CAUTION This procedure must be performed
for every burner.