Loading ...
Loading ...
Loading ...
en Installation and connection
8
Ignite all burners both individually and concurrently to
ensure correct operation of gas valves, burners and
ignition. Turn gas taps to low flame position and
observe stability of the flame for each burner
individually and all together. Adhere the duplicate data
plate to an accessible location near the hotplate. When
satisfied with the hotplate, please instruct the user on
the correct method of operation. In case the appliance
fails to operate correctly after all checks have been
carried out, refer to the authorised service provider in
your area.
It should be expressly noted that we cannot accept any
liability for direct or indirect damage caused by wrong
connection, leakage or improper installation. When
being repaired, the appliance must always be
disconnected from the mains supply; if required, notify
our customer service.
Converting the cooktop from Nat. Gas to
Universal LPG
All work involved in installation, setting and adaptation
to a different gas type must be carried out by
authorised personnel from our Service Centre and must
comply with current regulations and the conditions laid
down by the local gas company.
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
Important: After finishing, stick the sticker, indicating
the new gas type, close to the specifications plate.
Replacing the injectors
Request change-over injectors from our customer
service deparment (refer injector chart below for sizes).
1. Remove all pan supports, burner caps and
distributors.
2. To replace the injectors, use the key that is available
from our technical service with code 340847 (for
double-flame burners 340808). See table. It is
important to make sure that the injector does not
become detached during removal or fastening. They
must be properly tightened to ensure that there are
no leaks.
With these burners, there is no need to adjust the
primary air.
3. Fasten the distributors and burner caps to the
corresponding burners. In addition to this, put the
pan supports in place on the corresponding burners.
Adjusting the gas valves
The gas hob cover and the plug-in board must be
removed before you can adjust the gas valves.
Removing the cover:
1. Remove all pan supports, burner caps, distributors
and control knobs.
2. Undo the screws on the burners.
3. If necessary, use the removal lever (483196), which
is available from our after-sales service. Use the
lever to release the front clip fastener at the points
shown.
4. Carefully remove the cover.
Removing the plug-in board
The plug-in board is secured to the holder by fastening
pins at the sides and in the middle. Carefully press on
the plug-in board without damaging it. If one of the pins
breaks, the entire holder must be replaced.
Proceed as follows:
1. Release the pins on one side.
2. Release the middle pins. To do this, press down on
either side eith your fingers.
3. Release the pins on the other side and remove the
plug-in board.
Caution!
Handle the plug-in board with care. Use anti-static
protection, or handle the plug-in board by its edges.
Never touch the surfaces with components or tracks.
4. Remove the cylindrical parts and springs from the
gas valve stem.
Natural Gas Universal LPG
Hourly Gas
Consumption
(MJ)
Injector
mark
Hourly Gas
Consumption
(MJ)
Injector
mark
Economy
burner
4 88 3.5 50
Standard-
output
burner
6.85 116 6 66
High-output
burner
11 153 11 87
Dual wok
burner
5 kW
19.5
190
16.5
96
77 45


Loading ...
Loading ...
Loading ...