EMPTYING THE INTERNAL WATER TANK
MANUAL DRAINAGE:
When the internal water tank is full the unit will stop working.
Shut off the unit and unplug. Try not to move the appliance as this may cause the water in the internal tank to
spill out. Remove the water tank from the base of the unit and empty into a sink or drain. Replace the water
tank in the unit before plugging back in and restarting operation.
CONTINUOUS DRAINAGE:
Remove the water tank from the unit, and remove the rubber cap from the end of the drainage spout. Connect
the drainage pipe to the spout. Feed the drainage pipe through the hole in the side of the unit from the inside
before sliding the water tank back into place. The drain is gravity fed, so can be routed downwards to a suitable
drain. Alternatively the pipe can be attached to an external uplift pump (not supplied) to pump the water
uphill to a suitable drainage point.
NOTE: This model has a self-evaporative function, which reduces the need to empty the water tank. If the unit
is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. Please
do not use continuous drainage if you intend to use the self-evaporating facility.
CLEANING AND MAINTENANCE
PLEASE TURN OFF THE UNIT AND UNPLUG FROM THE MAINS BEFORE CLEANING OR PERFORMING ANY
MAINTENANCE
CLEAN THE SURFACE
Clean the surface of the machine with a wet soft cloth. Do not use chemicals, such as benzene, alcohol, gasoline, etc;
otherwise, as this may cause damage to the surface and or the internal workings of the machine
AIR FILTER CLEANING
If the filter screen is clogged with dust, the effectiveness of the air conditioner is reduced. The filter screen should be
cleaned once every two weeks or as often as necessarily in your environment.
END OF SEASON MAINTENANCE
1. Empty the internal water tank.
2. Then switch the unit to low fan mode.
3. Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep the inside of
the unit dry and prevents mould from developing
4. Turn off the unit and pull out the plug.
5. Empty the water tank again.
6. Coil the wire and bind it together, then put it into the accessories space.
7. Separate the vent pipes and store the, safely.
8. Cover the unit and keep it in a dry place.
Loading ...