Page 29
CB0522 through CB1030
Information Display
Cleaning
Push and release the Down arrow to put the line under the C in Cleaning.
Then push and release the Enter button to see.
Cleaning. Press and release the Enter button to see:
The Clean Interval
. Then press and release the Down arrow to see:
The Next Clean Due in x HRS
. Then press and release the Down arrow to
see:
Last Clean: x HR Ago
.
Then press and release the Down arrow to see:
Flush Level: Set to Auto or 1, 2, 3, 4 or 5.
Push and release the SEL arrow key to enter flush level set mode.
Push and release the Up or Down arrow keys to change flush level.
Push and release the Enter key to set the new flush level.
Then press and release the ESC button.
Push and release the Down arrow to put the line under the P in
Performance.
Then push and release the Enter button to see:
Performance
Percent run time
. Then press and release the Down arrow to see:
Min Freeze Time
. Then press and release the Down arrow to see:
Max Freeze Time.
Then press and release the Down arrow to see:
AVG Freeze Time
. Then press and release the Down arrow to see:
Min Harvest Time
. Then press and release the Down arrow to see:
Max Harvest Time
. Then press and release the Down arrow to see:
AVG Harvest Time
. Press the Down arrow to see the next screen
History screen. Press and release the SEL button to clear the performance
history.
When done with Performance, press and release the ESC button.
Status:
C
leaning
Clean Interval:
6 Months
Next Clean Due
in HRS
Last Clean:
9 Months Ago
Flush Level:
1
Set Flush Level:
3
Cleaning
P
erformance
Min Harvest Time
00:00
Max Harvest Time
00:00
AVG Freeze Time
00:00
Percent run time
0.00%
Min Freeze Time
00:00
Max Freeze Time
00:00
AVG Harvest Time
00:00
Clear History