The appliance must be placed in a room without sources of ignition (for example:
open ames, an operating gas appliance or an operating electric heater).
R290 refrigerant gas complies with European environmental directives.
R290 has a low GWP (Global Warming Potential) of 3.
The CD12LE contains about 60g of R290 refrigerant gas.
The CD20LE contains about 75g of R290 refrigerant gas.
Do not use or store the CD20LE in an unventilated space with an area smaller
than 4.1m2 per unit.
Do not use or store the CD12LE in an unventilated space with an area smaller
than 2.6m2 per unit.
If the appliance is installed, used or stored in an unventilated room, the room must
be such as to prevent stagnation of possible leaks of refrigerant gas as there
could be a danger of re or explosion should the refrigerant come into contact with
electric heaters, stoves or other sources of ignition.
Refrigerant gas may be odourless.
Do not use the product and contact the retailer for advice, if damage has occurred
to the unit which may have compromised the refrigerant system.
Any repairs or maintenance must only be carried out on the unit by a suitably
qualied engineer. Before opening and servicing the unit the authorized engineer
must be in possession of a copy of the manufacturer’s service manual and
must follow the safety information contained within it to ensure all hazards are
minimized.
The refrigerant system should not be perforated or punctured.
Do not place the unit next to heat sources (e.g. electrical res, replaces, etc.)
Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause
damage to its internals and increases the risks of operating it.
Do not store or use gasoline, petrol, paint, solvents or other ammable vapours or
liquids in the vicinity of this dehumidier or any other appliance.
This dehumidier must not be used in spaces where there is a high concentration
of gases, solvent or other volatile organic compounds; in very dusty environments;
in any domestic, commercial or industrial environment where the air composition
is ammable.
Do not cover or restrict the airow from the outlet or inlet grills. Do not operate and
follow troubleshoot procedure if the self-opening louvers do not open on power on.
For maximum performance the minimum distance from a wall or objects should be
20 cm
Keep the lters or grills of the unit clean. Under normal conditions, lters or grills
should only need cleaning once every three weeks (approximately).
Since the filters remove airborne particles, more frequent cleaning maybe
necessary, depending on the air quality. Vacuum both mesh and optional carbon
lters and wash the mesh lters with hot soapy water and dry them before placing
them back in the unit.
ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS