11
Step 2 Determine Mounting Location
Measuring and Marking for the Gate Bracket
Before proceeding, begin with the gate in the fully closed position. There are two methods for determining the proper location of the post brackets. Either
method will work depending on preference:
l Paper template (Located on the back page of this manual. Must be cut out.)
l Tape measure.
NOTE: There should only be a maximum of 4" (10.2 cm) from the center of the hinge to the edge of the post or column. If the distance is greater than 4"
(10.2 cm) entrapment protection for this area is required.
Template Method
1. Close the gate.
2. Place the template (provided on the back page of this manual) under
the center of the gate hinge point.
3. Use a screwdriver or dowel rod to temporarily mark the location in
front of the gate post.
OR
Tape Measure Method
1. Close the gate.
2. Place the measuring tape under the center of the gate hinge point
and measure out 7 inches (17.8 cm).
3. Use a screwdriver or dowel rod to temporarily mark the location of
the first measurement.
4. Measure 7 inches (17.8 cm) from the previous mark.
5. Use the screwdriver or dowel rod to mark the location of the second
measurement.
Alternate Dimensions
The ideal installation measurements are A = 7" (17.8 cm) and B = 7"
(17.8 cm). If different measurements are used, the sum of A and B
cannot be greater than 15" (38.1 cm).
DIMENSION CHART
A B
7" (17.8 cm) 7" (17.8 cm)
8" (20.3 cm) 6" (15.2 cm)
7-1/2" (19.1 cm) 7-1/2" (19.1 cm)
6-1/2" (16.5 cm) 6-1/2" (16.5 cm)
6" (15.2 cm) 6" (15.2 cm)
INSTALLATION
Loading ...
Loading ...
Loading ...