VENTILATION REQUIREMENTS
VENTILATION UNIT WALL INSTALLATION RECOMMENDATIONS
Hood
A min. 30" (762mm) max. 42 (762mm)
B min. 19" (480mm) max. 42 (762mm)
Blower
30" Range min. 550 CFM
36" Range min. 550 CFM
48" Range min. 1100 CFM
VENTILATION UNIT ISLAND INSTALLATION RECOMMENDATIONS
Hood
A min. 30" (762mm) max. 42 (762mm)
B min. 19" (480mm) max. 42 (762mm)
Blower
30" Range min. 550 CFM
36" Range min. 550 CFM
48" Range min. 1100 CFM
Non-combustible Non-combustibleCombustible Combustible
๎˜ƒz
Ventilation hoods and blowers are designed for use with single wall ducting, however some local building codes or inspectors may require double wall ducting and/or a damper. Consult๎˜žlocal
building codes and/or agencies before installing to ensure local requirements are met.
๎˜ƒz
Hood blower speeds should be variable to reduce noise and loss of household air. The maximum speed should only be required when using the grill or SELF CLEAN.
๎˜ƒz
Due to a high volume of ventilation air, a source of make-up air (outside replacement air) is recommended. This is particularly important for tightly sealed and insulated homes. A reputable
heating and ventilating contractor should be consulted.
B B
B b
A A
A A
WALL INSTALLATION ISLAND INSTALLATION