VENTILATION REQUIREMENTS
VENTILATION UNIT WALL INSTALLATION RECOMMENDATIONS
Hood
A min. 30" (762mm) max. 42 (762mm)
B min. 19" (480mm) max. 42 (762mm)
Blower
30" Range min. 550 CFM
36" Range min. 550 CFM
48" Range min. 1100 CFM
VENTILATION UNIT ISLAND INSTALLATION RECOMMENDATIONS
Hood
A min. 30" (762mm) max. 42 (762mm)
B min. 19" (480mm) max. 42 (762mm)
Blower
30" Range min. 550 CFM
36" Range min. 550 CFM
48" Range min. 1100 CFM
Non-combustible Non-combustibleCombustible Combustible
๎z
Ventilation hoods and blowers are designed for use with single wall ducting, however some local building codes or inspectors may require double wall ducting and/or a damper. Consult๎local
building codes and/or agencies before installing to ensure local requirements are met.
๎z
Hood blower speeds should be variable to reduce noise and loss of household air. The maximum speed should only be required when using the grill or SELF CLEAN.
๎z
Due to a high volume of ventilation air, a source of make-up air (outside replacement air) is recommended. This is particularly important for tightly sealed and insulated homes. A reputable
heating and ventilating contractor should be consulted.