Gorenje 7kg Vented Dryer D722CM

User Manual - Page 10

For D722CM.

PDF File Manual, 39 pages, Download pdf file

Loading ...
Loading ...
Loading ...
10
INSTALLATION AND
CONNECTION
SELECTING THE ROOM
10 cm
10 cm
5 cm
350077
Ventilation slots and the opening on the front and rear side should always be
kept free.
When installing the dryer in a room, note the required clearance as indicated
in the image. In case of failure to heed the required minimum clearance, the
dryer may overheat.
For condensation dryer
Do not install the appliance in a room where there is danger of frost.
The room in which the appliance is installed should be adequately ventilated,
with temperature between 10°C and 25°C. When the dryer is operated at a
lower ambient temperature, condensate can accumulate in the appliance
interior.Frozen water in the condensate tank or pump may damage the dryer.
For vented dryer
Place the appliance in well aerated room with a window or fitted with a fan.
Put the evacuation tube into the appropriate opening. Evacuation duct may
not be placed into the chimney or other type of air duct used for evacuation
of exhaust fumes and smoke of appliances using other combustible
substances.
Exhaust air must not be discharged into a flue which is used for
exhausting fumes from appliances burning gas or other fuels
Loading ...
Loading ...
Loading ...