Burner and nozzle specifications tables
60 cm models:
1 Natural Gas G20 - 20 mbar AUX SR RR UR
Rated heating capacity (kW)
1.10 1.80 2.60 3.50
Nozzle diameter (1/100 mm)
73 95 115 132
Reduced flow rate (W)
400 500 750 1600
Primary air (mm)
1111
2 Natural Gas G20 - 25 mbar AUX SR RR UR
Rated heating capacity (kW)
1.10 1.80 2.60 3.50
Nozzle diameter (1/100 mm)
73 87 110 126
Reduced flow rate (W)
400 500 750 1600
Primary air (mm)
1111.5
3 Natural Gas G25.1 - 25 mbar AUX SR RR UR
Rated heating capacity (kW)
1.00 1.80 2.60 3.50
Nozzle diameter (1/100 mm)
76 98 123 145
Reduced flow rate (W)
400 500 750 1600
Primary air (mm)
1 1 0.5 1.5
4 Natural Gas G25 - 20 mbar AUX SR RR UR
Rated heating capacity (kW)
1.10 1.70 2.60 3.50
Nozzle diameter (1/100 mm)
82 98 126 145
Reduced flow rate (W)
400 500 750 1600
Primary air (mm)
1 1 0.5 0.5
5 Natural Gas G27 - 20 mbar AUX SR RR UR
Rated heating capacity (kW)
1.10 1.70 2.60 3.50
Nozzle diameter (1/100 mm)
82 105 130 150
Reduced flow rate (W)
400 500 750 1600
Primary air (mm)
1 1 0.5 0.5
6 Natural Gas G2.350 - 13 mbar AUX SR RR UR
Rated heating capacity (kW)
1.10 1.80 2.60 3.50
Nozzle diameter (1/100 mm)
100 126 160 190
Reduced flow rate (W)
400 500 750 1600
Primary air (mm)
1111.5