Installation Manual 53
Function
ENGLISH
It is useful to check the cycle data without LGMV.
Operating Method
Whenever you push the Tact Switch, the cycle information will be shown as below.
h After 1page is displayed, subsequently 2page is displayed.
Tact S/W Item
Display
Example 1page 2page
1 time Low Pressure 890kpa ‘LP’ 89’
2 time Hi Pressure 2900kpa ‘HP’ ‘290’
3 time Discharge Temp. 85°C ‘DS’ 85’
4 time Cond Out Temp. -10°C ‘CS’ ‘-10’
5 time Suction Temp. -10°C ‘SS’ ‘-10’
6 time ODU Air Temp. -10°C ‘AS’ ‘-10’
7 time Current 15A ‘A ‘ 15’
8 time Voltage 230V ‘V’ ‘230’
9 time Comp Hz 100Hz ‘F’ ‘100’
10 time DC Link Voltage 230V ‘dc’ ‘230’
TACT-SW1
PCB Display(36,42kBtu/h class Model Only)
WARNING : When you push the Tact Switch, use the material non-
conducting electricity.