Operating Instructions and Owner’s ManualPortable Propane Cabinet Heater
CLEARANCE (Minimum clearances to combustible materials)
MODEL NO. BTU/HR RATING NORMAL OPERATING CLEARANCES TO
TYPE GAS POSTION COMBUSTIBLES
LP TOP SIDES BACK FRONT
MH18CH 18,000* VERTICAL 24” 12” 0” 72”
CONTENTS
Specifications and Warnings ............................................. 2
General Information .......................................................... 3
Installation Instructions .................................................. 3-4
Location ............................................................................ 5
Operating Instructions ...................................................... 5
Lighting and Shut Down ................................................... 6
Maintenance Instructions .................................................. 6
Replacement Parts List ................................................... 7-8
Service and Parts Ordering Information ............................. 9
The heater is designed and approved for use as a construction
heater under ANSI Z83.7b / CGA 2.14b - 2009
We cannot anticipate every use which may be made of our
heaters. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF
YOU HAVE QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat producing
products in specific applications. Your local authority can advise
you about these.
This appliance is intended to be used primarily for the heating of
buildings under construction, alteration or repair.
FOR YOUR SAFETY
Do not use this heater in a space where
gasoline or other liquids having flammable
vapors are stored or used.
WARNING
DO NOT EXCEED 14” W.C. (1/2 psi) INLET
PRESSURE TO HEATER.
SPECIFICATIONS
MODEL NO...................MH18CH
GAS TYPE..................... LP-Gas
GAS SUPPLY PRESSURE
TO REGULATOR.............MAX 200 psi (1380 kPa)
MIN 5 psi (34.5 kPa)
MANIFOLD
PRESSURE.....................11” W.C
VENTILATION
WARNING
THIS APPLIANCE IS UNVENTED AND MUST BE
USED ONLY IN A WELL VENTILATED AREA.
The flow of combustion and ventilation air must not be
obstructed. DO NOT use in a tightly enclosed area. Any
combustion process requires and consumes oxygen, and may
produce carbon monoxide. This heater must be operated with
adequate ventilation. Two openings directly to the outdoors must
be provided, one low and one high, preferably on opposite sides
of the area to be heated. Each of these openings must provide
at least three square inches of combustion air-intake area and
exhaust outlet area for every 1000 BTUs per hour of heater input
rate in order to complete the combustion/ventilation process.
Provide additional ventilation for any additional fuel-burning
appliances and/or additional occupants.
Do not exceed the gas supply pressures shown on rating plate
for Model MH18CH. The maximum inlet gas supply pressure and
the minimum inlet gas supply pressure (for purposes of input
adjustment) for LP-Gas are shown as follows:
*Tank size and tank temperature can directly affect BTU output
WARNING: Fuels used in liquefied propane
gas appliances, and the products of combustion of such
fuel, can expose you to chemicals including benzene, which
is known to the state of California to cause cancer and
cause birth defects or other reproductive harm, for more
information go to www.P65Warnings.ca.gov
WARNING:THIS PRODUCT CAN EXPOSE
YOUTOCHEMICALSINCLUDINGLEADANDLEAD
COMPOUNDS, WHICH ARE KNOWN TO THE STATE
OFCALIFORNIATOCAUSECANCERANDBIRTH
DEFECTS OR OTHER REPRODUCTIVE HARM. FOR MORE
INFORMATION VISIT WWW.P65WARNINGS.CA.GOV
NEVER LEANEVER LEANEVER LEAVE THE HEAVE THE HEAVE THE HEATER UNATER UNATER UNATTENDED WHILE BURNING!TTENDED WHILE BURNING!TTENDED WHILE BURNING!