MAINTENANCE
Oven Doors
Periodically oven door hinges may require added lubrication to work smoothly. Whether this is necessary or how
frequently will depend on how and how often you use your oven. Open the door fully and apply a small amount of
lubricant to the ball visible in the hinge slot on your door. We recommend a food grade light oil or grease. Cooking oil or
mineral oil may be used, but should be avoided if possible. Do not use sprays like WD-40 or CRC that may get onto the
oven door surface.
OVEN BULB REPLACEMENT
Only use a 40 Watt Appliance bulb. Regular light bulbs cannot tolerate oven temperatures.
1. Make sure oven is cool.
2. Grasp the clear globe lens with your fingers and turn counter clockwise to loosen and remove.
3. Replace the burned out bulb with a 40 Watt Appliance bulb.
4. Replace the clear globe by turning clockwise.
TOP BURNER LOW FLAME ADJUSTMENT
At its lowest setting, a properly adjusted burner will produce a steady flame about 1/8” above the burner ports. If your
flames do not appear, follow the instructions to adjust the flame height.
Before you begin, follow the steps in the Air Shutter Checklist.
1. Push and turn the burner fully counter clockwise to the lowest simmer setting. Leave burner on.
2. Remove the burner knob from the valve stem by pulling the knob straight toward you. Set the knob aside.
3. Use a wrench to secure the valve stem while you make the adjustments.
4. Insert a 1/8” flat-head screwdriver blade into the D” shaped valve stem and is inserted into the adjusting screw.
To lower the flame, turn the adjusting screw clockwise 1/8 of a turn at a time until the flame is at the desired
height.
To raise the flame, turn the adjusting screw counter clockwise 1/8 of a turn at a time until the flame is at the
desired height.
5. To replace the knob, align the D” shaped cut-out on the knob with the valve stem.
6. Push the knob straight onto the valve stem and turn the knob clockwise to the off position.
7. To check new burner height: Push and turn the burner knob counter clockwise to the lowest simmer. If you hear a
clicking sound but the burner does not ignite, repeat the steps to increase the flame height until the burner ignites and
remains lit at the lowest simmer setting.
TIP: This adjustment will also adjust the burner’s high flame setting.