Lynx L54TRF-LP Professional 54" Liquid Propane Freestanding Grill L54TRFLP

User Manual - Page 19

For L54TRF-LP.

PDF File Manual, 48 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
CARE & USE/INSTALLATION
|
19
FINAL CHECKS
LEAK TESTING
Leak Test Procedure:
Create a soapy solution of 1 part soap and 3 parts water.
Confirm that all control knobs are in the off position.
Turn on the fuel supply. For natural gas, turn the valve
handle 1/4 turn to align with the gas flow.
For L.P., turn the cylinder valve knob counter clockwise
one full rotation.
Apply the soap solution generously by paint brush or
squirt bottle on all connections and fittings.
If bubbles appear to “grow” on any of the connections,
you have a gas leak. IMMEDIATELY turn off the gas
supply.
Fixing a Gas Leak:
Shut off the gas supply
Turn all grill controls to the “ON” position to purge the
grill of any gas build-up, then turn the controls back
“OFF”.
Wash off the soapy solution with cold water and dry.
Tighten the loose joint, or replace the faulty part with
manufacturer-recommended replacement parts.
DO NOT attempt to repair the L.P. cylinder valve if it
is damaged. The only way to safely resolve a damaged
cylinder is to REPLACE IT.
Repeat the leak test to ensure that no leaks are present.
LOW HEAT BURNER ADJUSTMENT
FOR TRINDENT ™ BURNERS ONLY!
DO NOT ADJUST THE ROTISSERIE BURNER.
The Trident ™ burners on your Lynx grill feature an
adjustable low setting.
Fluctuations in gas pressure, gas conversion and even in the
quality of the gas itself may affect burner performance at the
“LOW” setting. It could be either too high or too low.
To Adjust the Burner to a Low Setting:
Make sure the grill is cool.
Light the burner and allow it to preheat on high for 3
minutes.
Turn the burner to “LOW”.
Pull off the control knob.
While holding the valve shaft with pliers as shown insert a
small flat screwdriver into the center shaft and adjust the
flame’s low setting. (1/8” blade 3” long shaft)
Clockwise will lower the flame setting, counterclockwise will
raise it.
The proper setting is where the flame is stable at its
lowest setting. A slight flutter will be present in the
crossover portion of the front of the Trident ™ burner before
the burner itself becomes weak.
The factory setting for propane gas is ½ to ¾ turn from the
very bottom of the adjustment. The setting for natural gas
is 1-½ to 1-¾ from the bottom. After the low settings are
proper, turn all burners to high for visual inspection.
To prevent fire or explosion hazard, DO NOT
smoke or allow any potential source of ignition
(sparks, electrical arcing, etc) in the area while
performing a leak test. Leak tests should be con-
ducted outdoors only. Never conduct a leak test
using fire or flame.
DANGER!
Loading ...
Loading ...
Loading ...