4
Electrical Requirements
WARNING
To prevent an electric-shock hazard, the power supply
must meet the specifications below. The owner shall
ensure that the electrical service meets electrical
requirements and that the electrical outlet is properly
installed by a licensed electrician.
A factory-installed 40-in. 3-prong grounding electrical plug
is connected to the chassis’s bottom right rear corner.
Product data label
Chassis Bottom
3-Prong
plug
Gas inlet
The cooktop must be connected to a dedicated, ground-
ed 3-prong electrical outlet installed by a licensed electri-
cian.
The electrical installation, including the supply wire size
and grounding, must be done according to National
Electric Code ANSI/NFPA 70* and local codes and ordi-
nances. A copy of this standard is available from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
The correct voltage, frequency, and amperage must be
supplied to the electrical outlet according to the product
data label on the chassis bottom (previous graphic).
See the Gas/Electrical Requirements table (this page).
Choose an easily accessible electrical outlet so the
power cord may be disconnected to service the cooktop.
Gas-Supply Requirements
Ensure the cooktop is correct for the gas (natural or liquid
propane) provided. If using the cooktop above 4000 ft.
(1219 m) elevation, ensure it is equipped for high-eleva-
tion operation.
Units equipped for liquid propane have “LP” in the model
number on the product data label (previous graphic).
Units equipped for high-elevation use have an “H” at the
end of the model number on the product data label.
Install the cooktop according to local building codes; if
none exist, install the appliance according to the National
Fuel Gas Code ANSI Z223.1/NFPA 54.
An external manual shut-off valve must be installed
between the gas inlet and cooktop so gas to the appli-
ance can be turned on/off.
The cooktop comes with its own regulator, which must be
installed in the gas line from the cooktop gas inlet to the
gas shut-off valve. Use only the regulator provided.
Models DTCT304G and -365G have a 1/2-in. regulator;
Model DTCT466G has a 3/4-in. regulator approved for
connection to a 1/2-in. house gas supply.
The cooktop gas connection is on the bottom of the chas-
sis, in the back right corner (previous graphic).
Gas/Electrical Requirements*
DTCT304G/NG,
-365G/NG, -466G/NG,
HPCT466G/NG
DTCT304G/LP,
-365G/LP, -466G/LP,
HPCT466G/LP
Gas type Natural Liquid propane
Manifold pressure 4” water column 10” water column
Min. gas-supply
pressure
5” water column** 11” water column**
Max. gas-supply
pressure
1/2 psi 1/2 psi
Total connected load 0.25 Amp. (0.03 kW) 0.25 Amp. (0.03 kW)
Circuit requirement 120 Vac, 60 Hz, 15 Amp 120 Vac, 60 Hz, 15 Amp
*This electrical/gas data is for reference only; in case of conflict, the data on
the product label takes precedence over the data in this table.
**The gas-supply pressure for testing the regulator setting shall be at least
1” water column (249 Pa) above the specified manifold pressure.