Loading ...
Loading ...
Loading ...
Conversion to another type of gas
49
Conversion from one type of gas
to another should only be
undertaken by an approved and
registered gas fitter in strict
accordance with current local and
national safety and building
regulations.
Disconnect the cooktop from the
electricity supply and turn off the gas
supply.
Jet table
The jet markings refer to a ¹/₁₀₀mm
bore diameter.
Main jet Small jet
NG
Auxiliary
burner
0.90 0.52
Semi-rapid
burner
1.10 0.52
Rapid burner 1.43 0.60
Wok burner 2x 1.27 / 0.90 0.44
ULPG
Auxiliary
burner
0.52 0.23
Semi-rapid
burner
0.66 0.36
Rapid burner 0.81 0.44
Wok burner 2x 0.70 / 0.46 0.25
Changing the jets
Disconnect the cooktop from the
electricity supply and turn off the gas
supply.
When converting to another type of
gas, both the main and small jets
need to be changed.
Changing the main jets
Auxiliary, semi-rapid and rapid
burners
Remove the pan support, burner
cap and burner head.
Using an M7 socket spanner,
unscrew the main jet.
Fit the correct jets securely (see jet
table).
Secure the jets against inadvertent
loosening with sealing wax.
Loading ...
Loading ...